This study investigated the effects of aerial ladder rung spacing on firefighter climbing biomechanics. Ten female and 9 male firefighters ascended and descended instrumented ladders with rungs spaced at 356mm (current design) and 305 mm in a laboratory setup. The climbing tests were performed at five ladder slope and handrail conditions: 30 degrees with low (305 mm) and high (914 mm) handrails, 52.5 degrees with and without a low handrail, and 75 degrees without a handrail. Foot and hand forces and body movements were recorded and used to calculate joint moments of the upper and lower body. Reduced rung spacing resulted in reduced foot forces, reduced hand forces, and reduced ankle transverse moment. It was also associated with increased climbing speed for female climbers, and increased ankle vertical overshoot. The results indicate that reduced rung spacing on aerial ladders may lead to lower biomechanical stress; better climbing efficiency and safety; and reduced climbing speed disparity across sexes.
机译:本研究调查了空中梯子间距对消防员攀岩生物力学的影响。十个女性和9名男性消防员升起和降临的梯子,梯级以356mm(当前设计)和305毫米在实验室设置中间隔开。攀爬试验在五个梯形斜坡和扶手条件下进行:低(305毫米)和高(914毫米)扶手30度,52.5度,扶手,没有扶手75度,没有扶手。记录脚和手力和身体运动,并用于计算上半身和下半身的关节矩。减少的梯间距导致脚力减少,手力减小,减少了脚踝横向时刻。它还与女性登山者的攀爬速度增加以及踝关节垂直过冲增加有关。结果表明,在空中梯子上减少的梯间距可能导致生物力学应力降低;更好的攀爬效率和安全;减少跨越性别的攀岩速度差异。