首页> 外文期刊>Acta Neurochirurgica >Feasibility of insertion of a microcatheter through a Y-stent in coil embolization of cerebral aneurysms and its detailed geometry by micro-computed tomography
【24h】

Feasibility of insertion of a microcatheter through a Y-stent in coil embolization of cerebral aneurysms and its detailed geometry by micro-computed tomography

机译:通过微型计算机断层摄影术在大脑动脉瘤的线圈栓塞及其详细的几何形状中通过Y型支架插入微导管的可行性

获取原文
获取原文并翻译 | 示例
           

摘要

Background: In Y-stent-assisted coil embolization for cerebral aneurysms, open or closed cell stents are used. Different microcatheters for coil insertion are available. We investigated which microcatheter could be navigated into an aneurysm through a Y-stent with different stents. Methods: Double Neuroform open-cell stents or double Enterprise closed-cell stents were deployed in Y-configuration in a silicon model of a bifurcation aneurysm. Two endovascular neurosurgeons independently tried to navigate an SL-10 microcatheter for 0.010" coils or a PX Slim microcatheter for 0.020" Penumbra coils into the aneurysm through the Y-stent. In addition, we measured lengths of stent pores of the Y-stents with double Enterprise stents deployed in the model by micro-computed tomography. Results: It was feasible to navigate an SL-10 microcatheter into the aneurysm through the Y-stent with Enterprise or Neuroform stents. Navigation of a PX Slim microcatheter was feasible in the Y-stents only with Neuroform stents. In the Y-stent with double Enterprise stents, the lengths of the second stent pores were significantly smaller than those of the first stent (0.41 ± 0.18 mm vs 0.69 ± 0.20 mm; P = 0.008). The SL-10 microcatheter was smaller than approximately 80 % of the stent pores of the first stent and 30 % of those of the second stent. The PX Slim microcatheter was smaller than 20 % of the stent pores of the first stent and 0 % of those of the second stent. Conclusions: It was feasible to insert an SL-10 microcatheter into the aneurysm through Y-stents with Enterprise or Neuroform stents. Navigation of a PX Slim microcatheter for 0.020" Penumbra coils was feasible in Y-stents with Neuroform stents, but not with double Enterprise stents. The measurements of stent pores by micro-computed tomography supported this feasibility study. These results may be helpful to select appropriate stents and microcatheters in Y-stent-assisted coil embolization, especially in case of retreatments.
机译:背景:在用于脑动脉瘤的Y型支架辅助线圈栓塞术中,使用了开放式或封闭式细胞支架。提供了用于插入线圈的不同微导管。我们调查了哪些微导管可以通过带有不同支架的Y型支架进入动脉瘤。方法:在分叉动脉瘤的硅模型中,以Y形配置双重Neuroform开孔支架或双重Enterprise闭孔支架。两名血管内神经外科医生独立尝试将用于0.010“线圈的SL-10微型导管或用于0.020”半影线圈的PX Slim微型导管通过Y型支架进入动脉瘤。此外,我们通过微计算机断层摄影术测量了在模型中部署的带有双重Enterprise支架的Y型支架的支架孔长度。结果:可以通过带有Enterprise支架或Neuroform支架的Y型支架将SL-10微导管导通进入动脉瘤。仅在使用Neuroform支架的Y型支架中,导航PX Slim微导管是可行的。在带有双Enterprise支架的Y型支架中,第二个支架孔的长度显着小于第一个支架的长度(0.41±0.18 mm对0.69±0.20 mm; P = 0.008)。 SL-10微导管小于第一个支架的支架孔的80%和第二个支架的支架孔的30%。 PX Slim微导管的直径小于第一个支架的支架孔的20%,小于第二个支架的支架孔的0%。结论:通过带有Enterprise支架或Neuroform支架的Y型支架将SL-10微导管插入动脉瘤是可行的。在带有Neuroform支架的Y型支架中,使用PX Slim微导管进行0.020“ Penumbra线圈导航是可行的,但对于双重Enterprise支架则不可行。通过微计算机断层摄影术对支架孔的测量支持了该可行性研究。这些结果可能有助于选择在Y型支架辅助的线圈栓塞中使用合适的支架和微导管,尤其是在进行重新治疗的情况下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号