...
首页> 外文期刊>Neurosurgery >Microcatheter Looping Technique for Coil Embolization of Complex Configuration Middle Cerebral Artery Aneurysms
【24h】

Microcatheter Looping Technique for Coil Embolization of Complex Configuration Middle Cerebral Artery Aneurysms

机译:微导管套环技术用于复杂构型中脑动脉瘤的线圈栓塞

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: Protection techniques using stents or microcatheters allow treatment of aneurysms with complex configurations by coil embolization. However, the application of these techniques is occasionally limited in wide-neck middle cerebral artery (MCA) aneurysms with acute angularity of the efferent branch vessel. OBJECTIVE: We describe a looping technique for passage of a microcatheter and microwire into the acutely angled efferent branch vessel without navigating the system through the aneurysm lumen.METHODS: To select the acutely angulated branch, a looped microcatheter was advanced near the orifice of the distal acutely angled branch vessel, followed by microwire passage through the looped microcatheter into the efferent vessel. The microcatheter loop was straightened after the microwire had been sufficiently advanced. The microcatheter was then navigated into the distal branch vessel over the advanced microwire.RESULTS: A total of 36 wide-neck MCA aneurysms were successfully treated using this looping method. This technique was used to pass the microcatheter for stent protection in 13 patients and for microcatheter protection in 23. The method was most commonly used for aneurysms located at the Ml trunk (n = 21), followed by the MCA bifurcation (n = 15). Complete or near-complete endosaccular occlusion was achieved in 31 aneurysms. There were no complications related to looping the microcatheter. CONCLUSION: This microcatheter looping technique facilitates safe entry into the distal branch during coil embolization of wide-neck MCA aneurysms incorporating the origins of acutely angulated branches.
机译:背景:使用支架或微导管的保护技术允许通过线圈栓塞治疗具有复杂构造的动脉瘤。但是,这些技术的应用有时会局限在具有分支分支急性锐角的宽颈大脑中动脉(MCA)动脉瘤中。目的:我们描述了一种微导管和微丝进入锐角传出分支血管而无需在动脉瘤腔内导航的循环技术。锐角分支血管,然后微丝穿过环状微导管进入传出血管。在将微丝充分推进之后,将微导管环拉直。然后,将微导管通过先进的微丝导航到远端分支血管中。结果:使用这种套环方法成功治疗了36例宽颈MCA动脉瘤。这项技术被用于通过微导管保护支架的13例患者和23例保护导管的方法。该方法最常用于位于M1主干(n = 21)的动脉瘤,然后用于MCA分叉(n = 15)。 。在31个动脉瘤中完成了完全或接近完全的囊内阻塞。没有与循环微导管有关的并发症。结论:这种微导管套环技术有助于在宽颈MCA动脉瘤的线圈栓塞过程中安全地进入远端分支,该分支合并了锐角分支的起源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号