BACKGROUND: CSF leakages constitute a major complication of intradural procedures, especially for posterior fossa and skull base surgery. Dural suture watertightness is a decisive issue, and neurosurgeons routinely use different products to reinforce their dural closure. We have designed an experimental system capable of testing CSF leak pressure levels in order to compare two types of sutures in vitro and particularly four different sealants. METHODS: Twenty-five fresh human cadaveric dural samples were removed and prepared for testing in a pressure chamber system connected to a hydraulic pressure motor. CSF leak levels were objectively registered. First, simple interrupted stitches were compared to running simple closure on 50-mm linear suture. Secondly, four sealants (two sealants/glues, Bioglue(R), Duraseal(R); two haemostatics, Tachosil(R), Tissucol(R)) were tested. Statistical analysis was performed with paired Student's t-test. RESULTS: No significant difference between interrupted closure and running suture was observed (p = 0.079). All sealants increased the watertightness of the suture significatively. However, comparison of the means of the differences for each product revealed large variations. In the conditions of our experiment, one sealant (Duraseal(R)) and one haemostatic (Tachosil(R)) seemed to show better results. We observed two different types of leakage: at the dura-sealant interface and through the sealant itself. CONCLUSIONS: We have developed an experimental device capable of testing dural closure watertightness. Interrupted stitch suturing seemed no different from running simple closure. On the contrary, the sealants tested show different watertightness capacities.
机译:背景:脑脊液渗漏是硬膜内手术的主要并发症,特别是对于后颅窝和颅底手术。硬膜缝合的水密性是一个决定性的问题,神经外科医师通常会使用不同的产品来加强其硬膜封闭。我们设计了一个能够测试CSF泄漏压力水平的实验系统,以比较两种体外缝合线,尤其是四种不同的密封胶。方法:取出二十五个新鲜的人体尸体硬脑膜样品,并准备在与液压马达相连的压力室系统中进行测试。 CSF泄漏水平已客观记录。首先,将简单的打断针脚与在50毫米的线性缝合线上进行简单的闭合进行比较。其次,测试了四种密封剂(两种密封剂/胶,Bioglue,Duraseal;两种止血剂Tachosil,Tissucol)。使用配对的学生t检验进行统计分析。结果:间断闭合和缝合运行之间无显着差异(p = 0.079)。所有密封剂均显着提高了缝合线的水密性。但是,对每种产品的差异均值进行比较后发现差异很大。在我们的实验条件下,一种密封剂(Duraseal®)和一种止血剂(Tachosil®)似乎显示出更好的效果。我们观察到两种不同类型的泄漏:在硬脑膜-密封剂界面处以及通过密封剂本身。结论:我们开发了一种能够测试硬脑膜封闭水密性的实验装置。断线缝合似乎与进行简单闭合没有什么不同。相反,测试的密封剂显示出不同的水密性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号