While 3-hydroxybenzo[a]pyrene (3-OHBaP) is a preferable biomarker to assess human exposure to benzo[a]pyrene (BaP), a sensitive and simple method is lacking. In this study, a specific and sensitive method based on liquid chromatography coupled with electrospray tandem mass spectrometry (LC-ESI-MS/MS) was developed for direct analysis of 3-OHBaP glucuronide and sulfate conjugates in human urine samples without enzymatic hydrolysis. The limits of detection (LODs) were 0.06 ng L-1 for BaP-3-sulfate (BaP-3-S) and 0.16 ng L-1 for BaP-3-glucuronide (BaP-3-G), which showed high sensitivity. Both compounds showed excellent linearity (r(2) > 0.99) in the range of 0.01-10 mu g L-1 in the instrumental calibration. The absolute recoveries of the target analytes spiked in human urine for the entire analytical procedure were 68.3 +/- 4.96% (mean +/- SD) and 63.7 +/- 5.47% for BaP-3-S and BaP-3-G, respectively. This method was applied to quantify BaP-3-G and BaP-3-S in 150 urine samples collected from healthy volunteers. The mean concentration of BaP-3-S was 0.67 ng g(-1) creatinine ( 98% of 3-OHBaP is excreted mainly in these two conjugated forms in human urine. A statistically significant positive association was observed between urinary 3-OHBaP conjugates and urinary 8-OHdG levels (p < 0.001) in the general population. This study developed a sensitive and simple method to determine urinary glucuronide/sulfate conjugated BaP metabolites and for the first time found that BaP exposure associated with 8-OHdG levels in the general population.
机译:虽然3-羟基苯苯并[a]芘(3-Ohbap)是优选的生物标志物,以评估人们暴露于苯并[a]芘(Bap),缺乏敏感和简单的方法。在该研究中,基于液相色谱法与电喷雾串联质谱(LC-ESI-MS / MS)相结合的特定和敏感方法,用于直接分析人尿样品中的3-Ohbap葡萄糖蛋白酶和硫酸盐缀合物,而不会酶水解。用于BAP-3-硫酸盐(BAP-3-S)和0.16ng L-1的检测限为0.06ng L-1,用于BAP-3-葡糖酸(BAP-3-G),其显示出高灵敏度。两种化合物在仪器校准中显示出优异的线性度(R(2)> 0.99),范围为0.01-10μgl-1。在人类尿液中整个分析程序掺入的目标分析物的绝对回收率为68.3 +/- 4.96%(平均+/- SD)和63.7 +/- 5.47%,BAP-3-S和BAP-3-G,分别。将该方法应用于从健康志愿者收集的150个尿液样本中量化BAP-3-G和BAP-3-S. BAP-3-S的平均浓度为0.67ng(-1)肌酐(98%的3-OHBAP以本两个缀合形式排出的人尿中的肌酐。在尿3-OHBAP缀合物之间观察到统计学上显着的阳性关联常规人群中的尿8-OHDG水平(P <0.001)。该研究开发了一种敏感和简单的方法,用于确定尿葡萄糖醛酸/硫酸盐缀合的膨胀代谢物,首次发现与8-OHDG水平相关的BAP暴露总人口。

著录项

  • 来源
    《Chemical research in toxicology》 |2019年第7期|共7页
  • 作者

    Luo Kai; Gao Qun; Hu Jianying;

  • 作者单位

    Peking Univ Coll Urban &

    Environm Sci MOE Lab Earth Surface Proc Beijing 100871 Peoples R China;

    Peking Univ Coll Urban &

    Environm Sci MOE Lab Earth Surface Proc Beijing 100871 Peoples R China;

    Peking Univ Coll Urban &

    Environm Sci MOE Lab Earth Surface Proc Beijing 100871 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 毒物学(毒理学);
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号