首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Validation and application of an ultrahigh-performance liquid chromatographic-Orbitrap mass spectrometric method for the simultaneous detection and quantification of volatile and non-volatile organic acids in human faecal samples
【24h】

Validation and application of an ultrahigh-performance liquid chromatographic-Orbitrap mass spectrometric method for the simultaneous detection and quantification of volatile and non-volatile organic acids in human faecal samples

机译:超高效液相色谱 - 横梁质谱法同时检测和定量人粪样品挥发性和非挥发性有机酸的验证及应用

获取原文
获取原文并翻译 | 示例
       

摘要

A simple and selective ultrahigh-performance liquid chromatographic-Orbitrap mass spectrometric (UHPLC-HR-MS) method was developed and validated for the simultaneous detection and quantification of short-chain fatty acids (SCFAs) such as acetic, propionic, butyric, isobutyric, valeric, isovaleric, 2-methyl-butyric (IS) and lactic, pyruvic and succinic acid in human faecal samples. A simple extraction procedure with 0.001% formic acid in water was performed on 40 samples. The extracts were centrifuged and analyzed by UHPLC-HR-MS on a sub-2 mu m column using gradient elution; meanwhile, the same samples were analyzed by GC-FID and HPLC-UV as reference methods The UHPLC-HR-MS method showed a recovery of 83-105%, a repeatability of 2.2-8.3% and an intermediate precision of 2.9-9.4%. The LOD and LLOQ were in the range of 0.04-0.23 and 0.2-0.5 mu g/ml,respectively. Regarding the SCFAs, statistical analysis showed a good correlation between the data obtained by UHPLC-HR-MS and those provided by GC-FID (p > 0.05). On the contrary, the LC-UV data were not in agreement with those obtained by UHPLC-HR-MS determination (p <0.05). To the best of our knowledge, this is the first method available for the simultaneous extraction and quantification of SCFAs, lactic, pyruvic and succinic in faecal samples by UHPLC-HR-MS. (C) 2017 Elsevier B.V. All rights reserved.
机译:开发了一种简单且选择性的超高性能液相色谱 - 横谱体质谱(UHPLC-HR-MS)方法,并验证用于同时检测和定量短链脂肪酸(SCFA),如醋酸,丙醇,丁基,异丙醛, valeric,脱戊烷,2-甲基 - 丁基(IS)和乳酸,丙酮酸和琥珀酸中的人粪便样品。在40个样品中进行水溶液中具有0.001%甲酸的简单提取方法。使用梯度洗脱将提取物离心并通过UHPLC-HR-MS分析亚2μm柱;同时,通过GC-FID和HPLC-UV分析相同的样品作为参考方法,UHPLC-HR-MS方法显示出83-105%,可重复性为2.2-8.3%,中间精度为2.9-9.4% 。 LOD和LLOQ分别为0.04-0.23和0.2-0.5μg/ ml。关于SCFA,统计分析显示通过UHPLC-HR-MS获得的数据与GC-FID提供的数据之间的良好相关性(P> 0.05)。相反,LC-UV数据与UHPLC-HR-MS测定获得的数据不一致(P <0.05)。据我们所知,这是UHPLC-HR-MS在粪便样品中同时提取和定量SCFA,乳酸,丙酮和琥珀酸的第一种方法。 (c)2017年Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号