An analytical method has been developed for the quantitative determination of the 16 EU priority polycyclic aromatic hydrocarbons (PAHs) in infant formula. Prior to analysis infant formula is subjected to sample preparation including the extraction of PAHs from the sample, transesterification of the triglyceride content of the extract to fatty acid methyl esters (FAMEs), and solid state urea clathrate formation to remove the FAMEs. Measurements were carried out with gas chromatography - tandem mass spectrometry. The developed method has been evaluated in terms of trueness, precision (repeatability), limit of detection (LOD), limit of quantification (LOQ), selectivity, sensitivity and linearity. Measurement range of 200-1500 ng kg(-1) was selected in accordance with the limit values set by the European Commission (835/2011/EC). LOD values were 75 ng kg(-1) for dibenzo(a,e)pyrene, dibenzo(a,i)pyrene and dibenzo(a,h)pyrene while 50 ng kg(-1) for the rest of the PAHs (benzo(c)fluorene, benzo(a)anthracene, cyclopenta(cd)pyrene, chrysene, 5-methylchrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(j)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, dibenzo(a,l)pyrene), LOQ was 200 ng kg(-1) for all 16 PAHs. Trueness ranged between -29.7 and 29.8% while precision values were between 0.5 and 24.7% (RSD, n=3).
机译:已经开发了一种分析方法,用于定量测定婴儿配方婴幼儿配方中的16欧盟优先态多环芳烃(PAH)。在分析之前,进行样品制剂,包括从样品中提取PAHs,酯化酯化提取物的甘油三酯含量为脂肪酸甲酯(FAME),以及固态尿素克拉酸盐形成以除去害虫。用气相色谱 - 串联质谱法进行测量。已经在特殊,精度(重复性),检测极限(LOD),定量限制(LOQ),选择性,灵敏度和线性的限制方面进行了评估。根据欧盟委员会(835/2011 / EC)设定的限制值选择200-1500 ng kg(-1)的测量范围。 LOD值为二苯脲(A,E)芘,二苯脲(A,I)芘和二苯脲(A,H)芘,而PAHS的其余部分(Benzo (c)芴,苯并(A)蒽,环戊类(CD)芘,蛹,5-甲基糠烯,苯并(B)氟烷,苯并(k)氟苯,苯并(j)氟苯,苯佐(a)芘,indeno(1 ,2,3- Cd)芘,二苯苯(A,H)蒽,苯并(G,H,I)丙烯,二苯脲(A,L)芘),LOQ为所有16pah为200ng kg(-1)。真实的范围在-29.7和29.8%之间,而精度值在0.5和24.7%之间(RSD,N = 3)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号