首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Silicone rod extraction followed by liquid desorption-large volume injection-programmable temperature vaporiser-gas chromatography-mass spectrometry for trace analysis of priority organic pollutants in environmental water samples
【24h】

Silicone rod extraction followed by liquid desorption-large volume injection-programmable temperature vaporiser-gas chromatography-mass spectrometry for trace analysis of priority organic pollutants in environmental water samples

机译:硅胶棒萃取,然后进行解吸-大体积进样-可编程温度蒸发器-气相色谱-质谱法对环境水样中的优先有机污染物进行痕量分析

获取原文
获取原文并翻译 | 示例
       

摘要

In this study a priority organic pollutants usually found in environmental water samples were considered to accomplish two extraction and analysis approaches. Among those compounds organochlorine compounds, pesticides, phthalates, phenols and residues of pharmaceutical and personal care products were included. The extraction and analysis steps were based on silicone rod extraction (SR) followed by liquid desorption in combination with large volume injection-programmable temperature vaporiser (LVI-PTV) and gas chromatography-mass spectrometry (GC-MS). Variables affecting the analytical response as a function of the programmable temperature vaporiser (PTV) parameters were firstly optimised following an experimental design approach. The SR extraction and desorption conditions were assessed afterwards, including matrix modification, time extraction, and stripping solvent composition. Subsequently, the possibility of performing membrane enclosed sorptive coating extraction (MESCO) as a modified extraction approach was also evaluated. The optimised method showed low method detection limits (3-35 ng L~(-1)), acceptable accuracy (78-114%) and precision values (<13%) for most of the studied analytes regardless of the aqueous matrix. Finally, the developed approach was successfully applied to the determination of target analytes in aqueous environmental matrices including estuarine and wastewater samples.
机译:在这项研究中,考虑了通常在环境水样中发现的优先有机污染物,以完成两种提取和分析方法。在这些化合物中,包括有机氯化合物,农药,邻苯二甲酸盐,苯酚以及药物和个人护理产品的残留物。提取和分析步骤基于硅胶棒提取(SR),然后进行液体脱附,并结合大体积注射可编程温度蒸发器(LVI-PTV)和气相色谱-质谱(GC-MS)。首先根据实验设计方法优化了影响作为可编程温度蒸发器(PTV)参数函数的分析响应的变量。随后评估SR萃取和解吸条件,包括基质改性,时间萃取和汽提溶剂组成。随后,还评估了进行膜包封吸附涂层萃取(MESCO)作为改进萃取方法的可能性。优化后的方法显示出低的检测限(3-35 ng L〜(-1)),可接受的准确性(78-114%)和大多数被分析物的精密度值(<13%),而与水性基质无关。最后,已开发的方法成功地应用于测定包括河口和废水样品在内的水性环境基质中的目标分析物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号