首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Determination of organic priority pollutants and emerging compounds in wastewater and snow samples using multiresidue protocols on the basis of microextraction by packed sorbents coupled to large volume injection gas chromatography-mass spectrometry analysis
【24h】

Determination of organic priority pollutants and emerging compounds in wastewater and snow samples using multiresidue protocols on the basis of microextraction by packed sorbents coupled to large volume injection gas chromatography-mass spectrometry analysis

机译:填充吸附剂与大体积进样气相色谱-质谱联用微萃取的多残留方案,采用多残留方案测定废水和积雪样品中的有机优先污染物和新兴化合物

获取原文
获取原文并翻译 | 示例
       

摘要

This paper describes the development and validation of a new procedure for the simultaneous determination of 41 multi-class priority and emerging organic pollutants in water samples using microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography-mass spectrometry (LVI-GC-MS). Apart from method parameter optimization the influence of humic acids as matrix components on the extraction efficiency of MEPS procedure was also evaluated. The list of target compounds includes polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs), bisphenol A (BPA) and selected steroid hormones. The performance of the new at-line microextraction-LVI-GC-MS protocol was compared to standard solid-phase extraction (SPE) and LVI-GC-MS analysis. LODs for 100mL samples (SPE) ranged from 0.2 to 736ngL~(-1) were obtained. LODs for 800μL of sample (MEPS) were between 0.2 and 266ngL~(-1). In the case of MEPS methodology even a sample volume of only 800μL allowed to detect the target compounds. These results demonstrate the high sensitivity of both procedures which permitted to obtain good recoveries (>75%) for all cases. The precision of the methods, calculated as relative standard deviation (RSD) was below 21% for all compounds and both methodologies. Finally, the developed methods were applied to the determination of target analytes in various samples, including snow and wastewater.
机译:本文介绍了一种新程序的开发和验证,该程序同时使用填充吸附剂(MEPS)进行微量萃取,然后采用大体积进样-气相色谱-质谱法(LVI-)同时测定水样品中的41种多类优先和新兴有机污染物GC-MS)。除方法参数优化外,还评估了腐殖酸作为基质组分对MEPS萃取效率的影响。目标化合物的清单包括多环芳烃(PAH),多氯联苯(PCB),邻苯二甲酸酯(PE),壬基酚(NP),双酚A(BPA)和某些类固醇激素。将新的在线微萃取LVI-GC-MS协议的性能与标准固相萃取(SPE)和LVI-GC-MS分析进行了比较。获得100mL样品(SPE)的LOD范围为0.2至736ngL〜(-1)。 800μL样品的最低检出限(MEPS)在0.2至266ngL〜(-1)之间。对于MEPS方法,甚至只有800μL的样品体积也可以检测目标化合物。这些结果表明,两种方法均具有很高的灵敏度,可以在所有情况下均获得良好的回收率(> 75%)。所有化合物和两种方法的方法相对于标准偏差(RSD)的精确度均低于21%。最后,将开发的方法用于测定包括雪和废水在内的各种样品中的目标分析物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号