首页> 外文期刊>Analytical chemistry >Identification and Quantification of Neuropeptides in Brain Tissue by Capillary Liquid Chromatography Coupled Off-Line to MALDI-TOF and MALDI-TOF/TOF-MS
【24h】

Identification and Quantification of Neuropeptides in Brain Tissue by Capillary Liquid Chromatography Coupled Off-Line to MALDI-TOF and MALDI-TOF/TOF-MS

机译:脱机耦合到MALDI-TOF和MALDI-TOF / TOF-MS的毛细管液相色谱法鉴定和定量脑组织中神经肽

获取原文
获取原文并翻译 | 示例
       

摘要

Capillary liquid chromatography (CLC) coupled off-line with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and TOF/TOF-MS were explored for identification and quantification of neuropeptides in microwave-fixed rat brain tissue. Sample was separated by gradient elution on 50-(mu)m-inner diameter reversed-phase columns at 180 nL/min. Effluent was mixed with matrix solution and transferred to a MALDI target plate by pulsed electric field deposition, yielding sample spots with 200-300-(mu)m diameter. Mass detection limits as low as 2 amol, corresponding to 1 pM concentration, were achieved for neuropeptides. CLC-MALDI-TOF-MS analysis of microwave-fixed rat striatum tissue yielded detection of over 400 distinctive peaks. CLC-MALDI-TOF/TOF-MS allowed identification of 10 peptides including 3 novel peptides. Quantification was evaluated using substance P as analyte and ~(15)N_(3)-labeled substance P as an internal standard. Quantification of substance P revealed approx6.8-fold higher levels than previously reported in the rat striatum. This increase is attributed to use of microwave fixation, which prevented degradation of the peptide, aggressive extraction procedures, and accounting for oxidation of substance P in the analysis. These results demonstrate that CLC-MALDI-TOF-MS is a versatile tool for neuropeptide analysis in brain tissue by allowing for detection, identification, and quantification.
机译:探索了离线与基质辅助激光解吸/电离飞行时间质谱(MALDI-TOF-MS)和TOF / TOF-MS耦合的毛细管液相色谱(CLC)用于鉴定和定量微波固定的神经肽大鼠脑组织。通过在50μm内径反相柱上以180nL / min的梯度洗脱来分离样品。将流出物与基质溶液混合,并通过脉冲电场沉积将其转移至MALDI目标板,从而产生直径为200-300-μm的样品点。神经肽的质量检测极限低至2 amol,相当于1 pM浓度。微波固定大鼠纹状体组织的CLC-MALDI-TOF-MS分析可检测到400多个不同的峰。 CLC-MALDI-TOF / TOF-MS可以鉴定10种肽,包括3种新肽。使用物质P作为分析物并使用〜(15)N_(3)标记的物质P作为内标评估定量。 P物质的定量显示其水平比先前在大鼠纹状体中报道的水平高约6.8倍。这种增加归因于微波固定的使用,该固定防止了肽的降解,积极的提取程序以及在分析中考虑了P物质的氧化。这些结果表明,CLC-MALDI-TOF-MS通过允许检测,鉴定和定量,是用于脑组织中神经肽分析的通用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号