Efficacy of antibiotics-loaded interpenetrating network (IPNs) hydrogel based on poly(acrylic acid) and gelatin for treatment of experimental osteomyelitis: in vivo study.

机译:基于聚丙烯酸和明胶的负载抗生素的互穿网络(IPNs)水凝胶在治疗实验性骨髓炎中的功效:体内研究。

获取原文
获取原文并翻译 | 示例

摘要

The safety and efficacy of gentamycin sulphate (GS)- or vancomycin hydrochloride (VCl)-loaded polymer devices based on poly(acrylic acid) and gelatin crosslinked selectively using 0.3mol % N,N'-methylene bisacrylamide and 1wt% glutaraldehyde were evaluated by varying the drug concentration onto the devices. The placebo and drug-loaded device of AxGx (acrylic acid:gelatin: 1:1 w/w) were employed for the treatment of experimental osteomyelitis in rabbit. Rabbits were categorized into four groups. Twelve rabbits in each group were treated with 12+/-1mg of AxGx-1a (22% w/w GS), 12+/-1mg of AxGx-1b (44% w/w GS), 16+/-1mg of AxGx-1b (44% w/w GS) and 16+/-1mg of AxGx-1c (44% w/w VCl). The drug concentration was measured following implantation in the adjacent tissue of femoral cavity, and serum. In femoral cavity maximum drug concentration was found on the 7th day with all the four types of devices. No drug was found after 21 days, at the local site with devices AxGx-1a and AxGx-1b (12+/-1mg), whereas it was detected after 6 weeks with 16+/-1mg device (44% w/w GS or VCl). Macroscopic evaluation after treatment revealed that swelling, redness, local warmth and drainage decreased depending upon the drug loading of the implants. Sequential radiographs, histology, microbiologic assay and scanning electron micrography demonstrated devices AxGx-1b and AxGx-1c (16+/-1mg of 44% w/w drug loading) to be the most suitable device, which heals the infection after 6 weeks of treatment. No significant difference (p>0.05) in the rate of healing was observed between GS- and VCl-loaded devices. None of the implant showed toxic level of drug in serum at any given time.
机译:通过使用0.3mol%N,N'-亚甲基双丙烯酰胺和1wt%戊二醛选择性交联的基于聚丙烯酸和明胶的载有硫酸庆大霉素(GS)或盐酸万古霉素(VCl)的聚合物装置的安全性和有效性进行了评估改变设备上的药物浓度。 AxGx的安慰剂和载药装置(丙烯酸:明胶:1:1 w / w)用于治疗实验性骨髓炎。将兔子分为四组。每组十二只兔子分别接受12 +/- 1mg AxGx-1a(22%w / w GS),12 +/- 1mg AxGx-1b(44%w / w GS),16 +/- 1mg AxGx-1b(44%w / w GS)和16 +/- 1mg AxGx-1c(44%w / w VCl)。植入邻近股骨组织和血清后测量药物浓度。在所有四种类型的装置中,第7天都在股骨腔中发现最大药物浓度。 21天后,在使用AxGx-1a和AxGx-1b(12 +/- 1mg)装置的本地站点未发现任何药物,而在使用16 +/- 1mg装置(44%w / w GS或VCl)。治疗后的宏观评估表明,肿胀,发红,局部温暖和引流减少取决于植入物的药物负荷。连续的X射线照片,组织学,微生物学测定法和扫描电子显微镜照片显示,设备AxGx-1b和AxGx-1c(16 +/- 1mg的载药量为44%w / w)是最合适的设备,可在感染6周后治愈感染。治疗。在装有GS和VCl的装置之间,未观察到治愈率的显着差异(p> 0.05)。在任何给定时间,植入物均未显示出血清中药物的毒性水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号