Since trans fat labeling requirements became mandatory in the US and many other countries, there has been a need for rapid and accurate analytical methodologies that can facilitate compliance with the various regulations. The determination of total trans fatty acids by mid-infrared (IR) spectroscopy is a widely used procedure that was standardized and validated as AOCS Official Method Cd 14e-09 (negative second derivative infrared spectroscopic method for the rapid (5 min) determination of total isolated trans fat) in 2009. The C-H out-of-plane deformation mid-IR band observed at 966 cm-1 is uniquely characteristic of isolated (non-conjugated) double bonds with trans configuration. AOCS Official Method Cd 14e-09, the most recent attenuated total reflection-Fourier transform IR (ATR-FTIR) official method, entails the measurement of the height of the negative second derivative of the trans absorption band. In the present study, the performance of a novel, portable FTIR system equipped with a heated 9-bounce diamond ATR crystal was evaluated and compared to that of a conventional benchtop single-bounce ATR-FTIR spectrometer. The introduction of the 9-bounce diamond ATR crystal resulted in the lowering of the limit of quantification of trans fat, as a percentage of the total fat, from approximately 2 to 0.34%. The data collected from accurately weighed gravimetric standards and 28 unknown test samples ranging in trans fat content from about 0.5 to 54%, as a percentage of the total fat, indicated that this IR official method and the use of the new 9-bounce portable ATR-FTIR instrumentation could lead to a five-fold enhancement in sensitivity relative to single-bounce systems. Implementing these changes would facilitate regulatory compliance and verification of fat and oil samples for trans fat content in the US and other countries, since all of the published regulations (e.g., "0 g trans fat per serving") have levels of trans fat, as percentage of total fat, that exceed 0.34%.Digital Object Identifier http://dx.doi.org/10.1007/s11746-011-1930-9
机译:自从 trans 脂肪标签要求在美国和许多其他国家成为强制性要求以来,就需要一种快速,准确的分析方法,以促进对各种法规的遵守。中红外光谱法测定总反式脂肪酸是一种广泛使用的方法,已标准化并验证为AOCS Official Method Cd 14e-09(负二阶导数红外光谱法,用于快速测定(5分钟)测定2009年的总分离反式脂肪。在966 cm -1 处观察到的CH面外变形中红外带是分离(非共轭)双链的独特特征与 trans 配置绑定。 AOCS官方方法Cd 14e-09是最新的衰减全反射傅里叶变换红外(ATR-FTIR)官方方法,需要测量反透射吸收带的负二阶导数的高度。在本研究中,评估了配备有加热的9反弹钻石ATR晶体的新型便携式FTIR系统的性能,并将其与常规台式单反弹ATR-FTIR光谱仪的性能进行了比较。 9弹钻石ATR晶体的引入使反式脂肪的定量极限(占总脂肪的百分比)从大约2%降低到0.34%。从精确称量的重量标准品和28个未知测试样品中收集的数据,其反式脂肪含量约占总脂肪的0.5%至54%,这表明该IR官方方法和相对于单反射系统,新型的9反射便携式ATR-FTIR仪器可将灵敏度提高五倍。由于所有已发布的法规(例如,“ 0 g 反式”),在美国和其他国家/地区实施这些更改将有助于法规遵从性和脂肪和油脂样品中反式脂肪含量的验证。 i>每份脂肪”)的反式脂肪含量占总脂肪的百分比超过0.34%。数字对象标识符http://dx.doi.org/10.1007/s11746-011- 1930-9

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号