The human body model (HBM) stress of a no-connect metal cover is tested to obtain the characteristics of abnormal electrostatic discharge, including current waveforms and peak current under varied stress voltage and device failure voltage. A new discharge model called the "sparkover-induced model" is proposed based on the results. Then, failure mechanism analysis and model simulation are performed to prove that the transient peak current caused by a sparkover of low arc impedance will result in the devices' premature damage when the potential difference between the no-connect metal cover and the chip exceeds the threshold voltage of sparkover.
机译:测试了未连接金属盖的人体模型(HBM)应力,以获得异常静电放电的特性,包括在变化的应力电压和设备故障电压下的电流波形和峰值电流。基于结果,提出了一种新的排放模型,称为“火花诱导模型”。然后,进行故障机理分析和模型仿真,以证明当未连接的金属盖和芯片之间的电势差超过阈值时,由低电弧阻抗的火花引起的瞬态峰值电流将导致器件过早损坏。火花放电电压。