首页> 美国卫生研究院文献>Revista Brasileira de Ortopedia >Comparison of Wear Rate between Ceramic-on-Ceramic Metal on Highly Cross-linked Polyethylene and Metal-on-Metal Bearings
【2h】

Comparison of Wear Rate between Ceramic-on-Ceramic Metal on Highly Cross-linked Polyethylene and Metal-on-Metal Bearings

机译:陶瓷陶瓷高交联聚乙烯上的金属和金属上金属轴承之间的磨损率比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective  Currently, there is a lack of evidence on the medium-term follow-up of cementless total hip arthroplasty (THA) using metal on highly cross-linked polyethylene (MoP), ceramic-on-ceramic (CoC), and metal-on-metal (MoM) bearings. Our aim was to calculate the 5- to 10-year wear rate and the incidence rate of osteolysis for 3 types of bearings. >Methods  A total of 77 patients underwent MoP, 105 underwent ceramic CoC, and 55 underwent MoM THAs. The average patient age at the time of surgery was 64.7, 55.9, and 59.9 years old in the MoP, CoC, and MoM bearings, respectively. Clinical and radiologic measurements at a mean follow-up of 7.6 years were analyzed. >Results  The mean postoperative Harris hip scores showed no difference among the groups. The mean annual liner wear rates were 0.0160, 0.0040 and 0.0054 mm/year in MoP, CoC bearings, and MoM bearings, with that of CoC bearings being significantly lower than the others. Osteolysis (14.5%) among MoM bearings was significantly more frequently observed compared with the others. Kaplan-Meier survival at 10 years with implant loosening, or revision THA as the endpoint, was 96.1% (95% confidence interval [CI]: 88.4–98.7) for MoP, 98.6% (95% CI: 90.3–98.6) for CoC bearing, and 98.2% (95% CI: 88.0–99.7) for MoM bearings ( p  = 0.360). >Conclusion  Excellent clinical and radiological outcomes were obtained for MoP and CoC bearings.
机译:>目的目前,缺乏在高交联聚乙烯(MoP)上,金属在陶瓷上(陶瓷)上进行非骨水泥全髋关节置换术(THA)的中期随访的证据。 CoC)和金属对金属(MoM)轴承。我们的目标是计算3种轴承的5至10年磨损率和溶骨发生率。 >方法共有77例患者接受了MoP,105例接受了陶瓷CoC,55例接受了MoM THA。在MoP,CoC和MoM轴承中,手术时的平均患者年龄分别为64.7、55.9和59.9岁。对平均随访7.6年的临床和放射学检查结果进行了分析。 >结果各组术后Harris髋关节平均评分无差异。 MoP,CoC轴承和MoM轴承的年平均衬套磨损率分别为0.0160、0.0040和0.0054毫米/年,而CoC轴承的年平均磨损率则明显​​低于其他轴承。与其他轴承相比,MoM轴承中的骨溶解(14.5%)更为频繁。 MoP的10年Kaplan-Meier生存率(MoP)为96.1%(95%置信区间[CI]:88.4-98.7),CoC为98.6%(95%CI:90.3-98.6)。轴承,MoM轴承为98.2%(95%CI:88.0-99.7)(p = 0.360)。 >结论 MoP和CoC轴承获得了出色的临床和放射学结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号