首页> 外文期刊>Clinical rehabilitation >Hip abductor control in walking following stroke -- the immediate effect of canes, taping and TheraTogs on gait.
【24h】

Hip abductor control in walking following stroke -- the immediate effect of canes, taping and TheraTogs on gait.

机译:中风后步行中的髋关节外展控制-拐杖,绑带和TheraTogs对步态的即时影响。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: To confirm previous findings that hip abductor activity measured by electromyography (EMG) on the side contralateral to cane use is reduced during walking in stroke patients. To assess whether an orthosis (TheraTogs) or hip abductor taping increase hemiplegic hip abductor activity compared with activity during cane walking or while walking without aids. To investigate the effect of each condition on temporo-spatial gait parameters. DESIGN: Randomized, within-participant experimental study. SETTING: Gait laboratory. SUBJECTS: Thirteen patients following first unilateral stroke. INTERVENTION: Data collection over six gait cycles as subjects walked at self-selected speed during: baseline (without aids) and in randomized order with (1) hip abductor taping, (2) TheraTogs, (3) cane in non-hemiplegic hand. MAIN MEASURES: Peak EMG of gluteus medius and tensor fascia lata and temporo-spatial gait parameters. RESULTS: Cane use reduced EMG activity in gluteus medius from baseline by 21.86%. TheraTogs increased it by 16.47% (change cane use-TheraTogs P = 0.001, effect size = -0.5) and tape by 5.8% (change cane use-tape P = 0.001, effect size = -0.46). In tensor fascia lata cane use reduced EMG activity from baseline by 19.14%. TheraTogs also reduced EMG activity from baseline by 1.10% (change cane use-TheraTogs P = 0.009, effect size -0.37) and tape by 3% (not significant). Gait speed (m/s) at: baseline 0.44, cane use 0.45, tape 0.48, TheraTogs 0.49. CONCLUSION: Hip abductor taping and TheraTogs increase hemiplegic hip abductor activity and gait speed during walking compared with baseline and cane use.
机译:目的:为了证实以前的发现,在卒中患者行走过程中,通过使用肌电图(EMG)测量的对侧拐杖对侧髋关节外展器活动性降低。评估矫形器(TheraTogs)或髋外展器绑带与手杖行走过程中或没有助行器行走时的活动相比是否增加了偏瘫性髋外展器活动。调查每种条件对时空步态参数的影响。设计:随机参与研究。地点:步态实验室。受试者:十三例单侧中风后。干预:受试者在6个步态周期内以自选速度行走时收集数据:基线(无辅助装置)并以随机顺序进行,其中(1)绑扎髋关节绑带,(2)TheraTogs,(3)非偏瘫手。主要测量指标:臀肌和张量筋膜的峰值肌电图和时空步态参数。结果:甘蔗使臀肌的EMG活性较基线降低了21.86%。 TheraTogs将其增加了16.47%(更改手杖使用-TheraTogs P = 0.001,效果尺寸= -0.5),胶带增加了5.8%(更改手杖使用胶带P = 0.001,效果尺寸= -0.46)。在张量筋膜筋膜中使用EMG较基线降低了19.14%。 TheraTogs还使EMG活性相对于基线降低了1.10%(更改手杖使用-TheraTogs P = 0.009,效果大小为-0.37),胶带降低了3%(不显着)。步态速度(m / s)为:基线0.44,拐杖使用0.45,胶带0.48,TheraTogs 0.49。结论:与基线和手杖使用相比,髋关节外展器绑带和TheraTogs可以提高步行过程中偏瘫性髋外展器活动和步态速度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号