This study measured displacement of canal centers in extracted human teeth after preparation by Lightspeed and nickel-titanium K-files. The specimens were divided into two groups (n = 11), after radiographing the roots from the buccolingual and mesiodistal planes with pathfinding files in situ. More strongly and less strongly curved canals were, respectively, assigned to the Lightspeed and nickel-titanium K-file groups. Using a reassembly technique, cross-sections at 1.25 mm, 3.25 mm, and 5.25 mm from the apices were made of the experimental roots embedded in clear plastic. Stereomicroscopic 35-mm slides were taken of the uninstrumented sectioned canals. The sections were reassembled and then prepared to size 50 Master Apical Rotary and size 40 Master Apical Files, for the Lightspeed and K-file groups, respectively. Similar 35-mm slides of the instrumented canals were taken and electronically superimposed over their uninstrumented counterparts. Displacements of root canal centers after preparation and increases in cross-sectional areas of the prepared root canals were evaluated at specific levels. No significant differences in displacement of canal centers or between the mean cross-sectional areas of the instrumented root canals were recorded between the Lightspeed and K-file groups. Both types of instruments produced similar displacement of canal centers after preparation.
机译:这项研究通过Lightspeed和镍钛K锉测量了拔牙后拔除人牙的根管中心位移。将标本从颊舌平面和近中坚平面的根部放射照相,并在原位设置寻路锉后,将标本分为两组(n = 11)。分别将更强和不太强的弯曲管分配给Lightspeed和镍钛K锉组。使用重新组装技术,从根部截取的1.25 mm,3.25 mm和5.25 mm的横截面是由嵌入透明塑料中的实验根制成的。取未器械切开的运河的立体显微镜35毫米幻灯片。重新组装这些部分,然后分别为Lightspeed和K-file组准备大小为50的主根尖旋转和大小为40的主根尖锉。取出类似的35毫米器械管的玻片,并以电子方式叠加在未器械的对应管上。在特定水平上评估准备后的根管中心位移和准备的根管横截面积的增加。在Lightspeed组和K型锉刀组之间,没有发现根管移位或根管平均横截面积之间的显着差异。两种器械准备后产生的根管中心位移相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号