首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >Heterophile antibodies may falsely increase or decrease thyroglobulin measurement in patients with differentiated thyroid carcinoma.
【24h】

Heterophile antibodies may falsely increase or decrease thyroglobulin measurement in patients with differentiated thyroid carcinoma.

机译:异种抗体可能会在分化型甲状腺癌患者中错误地增加或减少甲状腺球蛋白的测定。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: To examine the prevalence of significant interference from heterophile antibodies (HAb) in the measurement of serum thyroglobulin (Tg), we evaluated a large cohort of samples from patients with differentiated thyroid carcinoma (DTC). METHODS: Serum Tg measurements were performed in 406 serum samples before and after incubation of each serum sample in heterophile-blocking tubes (HBT) at room temperature for 1 h. We calculated the difference between the original Tg value and the value obtained after HBT treatment. We considered any sample showing an absolute percent difference >3 SD from the mean percent difference as being affected by HAb interference. RESULTS: We identified five patients (1%) as showing interference from HAb. Of these, three (60%) showed a false positive or falsely increased Tg concentration without any recurrence following clinical work-up; two (40%) showed a false negative or falsely reduced Tg levels, and metastases were detected in both cases by imaging procedures. CONCLUSIONS: HAb may increase as well as reduce the measured Tg in a significant number of patients. A positive HAb interference should be suspected if Tg elevation does not fit the clinical pictures. A negative interference is a more challenging problem because increases in Tg generally occur as the first sign of recurrence of DTC. Therefore, treatment using HBT tubes of all sera referred for Tg measurement should be considered in order to prevent both unwarranted investigations or therapy, and delayed diagnosis of recurrence in patients affected by DTC.
机译:背景:为了检查在测量血清甲状腺球蛋白(Tg)中来自嗜异性抗体(HAb)的显着干扰的患病率,我们评估了来自分化型甲状腺癌(DTC)患者的大量样本。方法:在406份血清样品中进行血清Tg测定,将每种血清样品在嗜异性封闭管(HBT)中于室温孵育1 h之前和之后。我们计算了原始Tg值与HBT处理后获得的值之间的差。我们认为任何显示出平均百分比差大于3 SD的样本均受HAb干扰的影响。结果:我们确定了5名患者(1%)显示出来自HAb的干扰。其中,三名(60%)的Tg浓度呈假阳性或假增加,临床检查后未见任何复发。 2名(40%)的Tg假阴性或假降低,并且在两种情况下均通过影像学检查发现了转移。结论:在许多患者中,HAb可能会增加以及降低测得的Tg。如果Tg升高不符合临床表现,则应怀疑HAb阳性。负干扰是一个更具挑战性的问题,因为Tg的升高通常是DTC复发的第一个迹象。因此,应考虑使用所有血清的HBT管进行Tg测量,以防止进行不必要的研究或治疗,以及避免受DTC影响的患者的复发诊断延迟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号