首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Development and validation of a high throughput and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of diltiazem and its two metabolites in human plasma: Application to a bioequivalence study
【24h】

Development and validation of a high throughput and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of diltiazem and its two metabolites in human plasma: Application to a bioequivalence study

机译:高通量且功能强大的LC-MS / MS电喷雾电离方法的开发和验证,用于同时定量人血浆中地尔硫卓及其两种代谢物:在生物等效性研究中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and C-desacetyldiltiazem) in human plasma. A one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether(MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC (TM) BEH C-18 column (100 mm x 2.1 mm. i.d., 1.7 mu m) with isocratic elution at a flow rate of 0.2 ml/min using 10 mM ammonium acetate buffer-acetonitrile (25:75, v/v). The Quattro Premier XE LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Using 300 mu L plasma, the method was validated over the concentration range 0.48-639.9 ng/mL for DLTZ and 0.24-320.1 for DMeD and 0.24-320.7 ng/ml for DAcD, with a lower limit of quantification of 0.48 ng/mL for DLTZ and 0.24 ng/ml. for metabolites. The intra- and inter-clay precision and accuracy were within 10.0%. The recovery was 77.4%, 76.0%, 74.5% and 74.1% for DLTZ, DMeD, DAcD and Ziprasidone, respectively. Total run time was 2.0 min only.
机译:开发了一种使用超高效液相色谱串联质谱(UPLC-MS / MS)的高通量且特定方法,用于同时测定人血浆中地尔硫卓及其两种代谢物(N-去甲基地尔硫卓和C-去乙酰基地尔硫卓)。用甲基叔丁基醚(MTBE)进行的一步液-液萃取(LLE)涉及地尔硫卓(DLTZ),代谢产物(DMeD和DAcD)和内标的萃取。使用10 mM乙酸铵缓冲液-乙腈在ACQUITY UPLC(TM)BEH C-18色谱柱(100 mm x 2.1 mm.id,1.7μm)上进行等度洗脱,以0.2 ml / min的流速进行色谱分离。 :75,v / v)。 Quattro Premier XE LC-MS / MS使用电喷雾电离技术在多重反应监控模式(MRM)下运行。使用300μL血浆,该方法在DLTZ浓度范围为0.48-639.9 ng / mL,DMeD浓度范围为0.24-320.1和DAcD浓度范围为0.24-320.7 ng / mL范围内得到验证,下限的定量范围为0.48 ng / mL DLTZ和0.24 ng / ml。用于代谢物。粘土内和粘土间的精度和准确度均在10.0%以内。 DLTZ,DMeD,DAcD和Ziprasidone的回收率分别为77.4%,76.0%,74.5%和74.1%。总运行时间仅为2.0分钟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号