Repositioning a decentered intraocular lens with 4 haptics

机译:用4个触觉重新定位偏心眼内镜

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We describe a technique to reposition a decentered 4-haptic intraocular lens (IOL). Using an ophthalmic viscosurgical device, the haptic with the worst distortion is dissected from the capsular bag and pulled outside the bag. The opposite haptic (180 degrees away) is also dissected and placed in front of the anterior capsule. The remaining 2 haptics are left in the capsular bag. With this repositioning, the 2 haptics in the bag limit the IOL movement, the 2 haptics outside the bag are no longer distorted, and the IOL is centered. We present 2 cases in which this technique was used to reposition decentered 4-haptic IOLs. (c) 2016 ASCRS and ESCRS
机译:我们描述了一种重新定位偏心的4-触觉人工晶状体(IOL)的技术。使用眼科内窥镜手术设备,将畸形最严重的触觉体从囊袋中切开并拉出该囊袋。还解剖了相对的触觉(相距180度)并将其放置在前囊的前面。其余2个触觉件留在囊袋中。通过这种重新定位,袋子中的2个触觉会限制IOL的运动,袋子外部的2个触觉不会再变形,并且IOL居中。我们介绍了2个案例,其中此技术用于重新定位偏心的4-触觉IOL。 (c)2016年ASCRS和ESCRS