首页> 外文期刊>Journal of Analytical Toxicology >Comparison of LC-MS-MS and GC-MS Analysis of Benzodiazepine Compounds Included in the Drug Demand Reduction Urinalysis Program
【24h】

Comparison of LC-MS-MS and GC-MS Analysis of Benzodiazepine Compounds Included in the Drug Demand Reduction Urinalysis Program

机译:减少毒品需求尿液分析程序中包含的苯二氮卓类化合物的LC-MS-MS和GC-MS分析的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Liquid chromatography-tandem mass spectrometry (LC-MS-MS) offers specific advantages over gas chromatography-mass spectrometry (GC-MS) such as the ability to identify and measure a broader range of compounds with minimal sample preparation. Comparative analysis of LC-MS-MS versus GC-MS was performed for urinalysis detection of five benzodiazepine compounds currently part of the Department of Defense (DoD) Drug Demand Reduction Program (DDRP) testing panel; alpha-hydroxyalprazolam, oxazepam, lorazepam, nordiazepam and temazepam. In the analyses of internally prepared control urine samples at concentrations around the DDRP administrative decision point for benzodiazepines (100 ng/mL), both technologies produced comparable results with average accuracies between 99.7 and 107.3% and average coefficients of variation (%CV) < 9%. Analysis of service member specimens that screened positive for benzodiazepines using both technologies produced comparable results for all analytes. Different degrees of matrix effect were observed for all analytes in the LC-MS-MS analysis. However, the effects were controlled by using deuterated internal standards (ISTDs). Additionally, there was a 39% increase in nordiazepam mean concentration analyzed by LC-MS-MS due to suppression of the ISTD ion by the flurazepam metabolite 2-hydroxyethylflurazepam. The ease and speed of sample extraction, the broader range of compounds that can be analyzed and shorter run time make the LC-MS-MS technology a suitable and expedient alternative confirmation technology for benzodiazepine testing.
机译:液相色谱-串联质谱(LC-MS-MS)提供了优于气相色谱-质谱(GC-MS)的特定优势,例如能够以最少的样品制备来识别和测量更广泛的化合物。进行了LC-MS-MS与GC-MS的对比分析,以检测尿液中五种苯二氮卓类化合物的含量,这些化合物目前是国防部(DoD)药物需求减少计划(DDRP)测试小组的一部分; α-羟基阿普唑仑,奥沙西m,劳拉西m,去甲西ze和替马西m。在分析内部制备的对照尿液样品中,浓度约为DDRP管理决策点的苯二氮卓类(100 ng / mL)时,两种技术均产生了可比的结果,平均准确度在99.7至107.3%之间,平均变异系数(%CV)<9 %。使用这两种技术对苯二氮卓类药物筛查呈阳性的服务成员标本的分析得出所有分析物的结果均相当。在LC-MS-MS分析中,对所有分析物观察到不同程度的基质效应。但是,通过使用氘代内标(ISTD)可以控制效果。此外,由于氟西epa代谢物2-羟乙基氟西epa抑制了ISTD离子,因此通过LC-MS-MS分析得出的降氮西ze平均浓度增加了39%。样品提取的简便快捷,可分析的化合物范围更广,运行时间更短,使LC-MS-MS技术成为苯二氮卓类检测的合适且方便的替代确认技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号