The combined effect of both concentration and pressure differences on electrical potential (DELTA PHI) for two ion-exchanger membranes, one positively charged (AE) and another negatively charged (CE), measured with the membranes in contact with NaCl solutions was studied. Results show a linear dependence between DELTA PHI and pressure, independently if DELTAC and DELTAP have the same or oposite directions. The ratio of the streaming potential for catin/anion exchange membranes is 4=(2.1(+-)0.4). A "bipolar" membrane (BM) was obtained by joining together both ion-exchanger membranes. In order to correlate the behaviour of the BP membrane with that corresponding to each sublayer, the same kind of measurements was carried out for both opposite external conditions, this means, applying the pressure on the cation exchanger (CABM) or on the anion exchanger membrane (ACBM), respectively. From values obtained at DELTAP-0, the counter-ion transport number in each ion-exchange membrane was obtained and the contribution of membrane potential on DELTAPHI values can be evaluated. Results show clear difference son both the membrane potential and the effect of pressure in the bipolar membrane depending on these two external situations, and in this case the ratios are: r~(CABM/ACBM)=(2.2(+-)0.4), r~(CABM/CE)=(5.0(+-)1.2) and r~(ACBM/AE)=(4.9(+-)0.3); higher influence of the anion exchange sublayer on the electrical potential difference values was obtained. A reduction around 75-85% in the transport number of the ions in the bipolar membrane with respect to that corresponding at each charged sublayer was estimated.
机译:研究了两个离子交换膜(一个带正电(AE)和另一个带负电(CE))的浓度和压力差对电势(DEL PHI)的综合影响,该膜在与NaCl溶液接触的情况下进行了测量。如果DELTAC和DELTAP方向相同或相反,则结果显示DELTA PHI和压力之间呈线性关系。阳离子/阴离子交换膜的流动电位之比为4 =(2.1(±)0.4)。通过将两个离子交换膜连接在一起获得“双极”膜(BM)。为了使BP膜的行为与对应于每个子层的行为相关联,在两种相反的外部条件下都进行了相同类型的测量,这意味着在阳离子交换剂(CABM)或阴离子交换剂膜上施加压力(ACBM)。从在DELTAP-0获得的值,获得每个离子交换膜中的抗衡离子迁移数,并且可以评估膜电势对DELTAPHI值的贡献。结果表明,取决于这两种外部情况,双极膜的膜电位和压力影响均存在明显差异,在这种情况下,比率为:r〜(CABM / ACBM)=(2.2(+-)0.4), r〜(CABM / CE)=(5.0(+-)1.2)和r〜(ACBM / AE)=(4.9(+-)0.3);获得了阴离子交换子层对电势差值的更大影响。估计相对于每个带电子层的离子,双极膜中离子的迁移数减少了约75-85%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号