摘要

Background Antiprothrombin antibodies detection comprises two different ELISAs: prothrombin coated on irradiated plates (aPT) or phosphatidylserine/ prothrombin (aPS/PT) as the antigen. While several commercial kits are available for the detection of aPT, aPS/PT are usually detected by in-house assays. Recently, a new commercially available kit was launched and, therefore, we decided to test its efficiency by comparing it to our in-house assay. Methods aPS/PT were tested by our in-house assay (aPS/PTih) in 75 SLE patients, using Immulon 1 plates coated with phosphatidylserine, purified human prothrombin and 1%BSA-TBS-CaCl as blocking and diluents. Data from this assay were compared to those obtained by the QUANTA Lite? aPS/PT screen, IgG and IgM Elisa (INOVA Diagnostics, Inc, San Diego, USA) commercial kits (aPS/PT c). Results aPS/PT were found in 41.3% and 46.7% of SLE patients by the aPS/PTih and the aPS/PTc, respectively. There was a positive correlation between IgG aPS/PTih and aPS/PTc assays (R2 = 0. 861 by Spearman test, p = 0.0027). Sensitivity and specificity for APS were 62.2% and 97.4% (AUC 0.780) for the aPS/PTih assay and 70.3% and 84.2% (AUC 0.858) for the aPS/PTC. Shorter running times were also seen when comparing the aPS/PTih vs. aPS/PTc (7 hours vs. 3 hours, respectively). Conclusion The aPS/PTC is a reproducible and accurate test for the detection of aPS/PT, bringing also the advantage of shorter running times.
机译:背景技术抗凝血酶原抗体检测包括两种不同的ELISA:涂在辐射板上的凝血酶原(aPT)或磷脂酰丝氨酸/凝血酶原(aPS / PT)作为抗原。尽管有几种商用试剂盒可用于检测aPT,但通常通过内部分析来检测aPS / PT。最近,推出了一种新的市售试剂盒,因此,我们决定通过将其与我们的内部检测方法进行比较来测试其效率。方法采用我们的内部检测(aPS / PTih)在75位SLE患者中使用涂有磷脂酰丝氨酸,纯化的人类凝血酶原和1%BSA-TBS-CaCl的Immulon 1板作为封闭剂和稀释剂,对aPS / PT进行了测试。将来自该测定的数据与通过QUANTA Lite?获得的数据进行比较。 aPS / PT屏幕,IgG和IgM Elisa(INOVA Diagnostics,Inc,美国圣地亚哥)商业试剂盒(aPS / PT c)。结果通过aPS / PTih和aPS / PTc分别在SLE患者中发现aPS / PT占41.3%和46.7%。 IgG aPS / PTih与aPS / PTc分析之间存在正相关(通过Spearman检验,R2 = 0. 861,p = 0.0027)。对于aPS / PTih分析,APS的敏感性和特异性分别为62.2%和97.4%(AUC 0.780),对aPS / PTC的敏感性和特异性分别为70.3%和84.2%(AUC 0.858)。比较aPS / PTih与aPS / PTc时,运行时间也更短(分别为7小时和3小时)。结论aPS / PTC是检测aPS / PT的可重复且准确的测试,还具有运行时间更短的优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号