首页> 外文期刊>Quintessence international >A comparative study on the use of digital panoramic and periapical radiographs to assess proximal bone height around dental implants
【24h】

A comparative study on the use of digital panoramic and periapical radiographs to assess proximal bone height around dental implants

机译:使用数字全景和根尖周射线照相评估牙种植体周围的近端骨高的比较研究

获取原文
获取原文并翻译 | 示例

摘要

Objective: The purpose of this study was to compare periapical radiographs (PA) and panoramic radiographs (PAN) in the measurement of proximal bone height around implants. Method and Materials: Patients files that contained digital PAN and PA together with information on implant lengths and diameters were selected for this study. For each radiograph, the implant size served as reference for calibration. Proximal radiographic bone levels and the linear distance between the bone crest and implant shoulder were measured twice by one examiner. Paired t test was used to assess intra-examiner variability and differences between the two radiographic methods. Correlation was then assessed using Pearson correlation coefficient test. Significance level was determined at 5%. Results: For the PAN measure-ments, the median mesial distances from bone crest to implant shoulder were 0.53 and 0.56 mm (first and second sets, P = .53). Likewise, for distal measurements these readings were 0.92 and 0.86 mm respectively (P = .66). For PA measurements, the corresponding measurements were 0.33 and 0.44 mm (P = .48) and 0.99 and 0.99 mm (P = .42), respectively. When PAN and PA measurements were compared, no statistically significant differences were detected between the two radiographic modalities. A very high positive correlation (r > 0.91) was attained for the PAN - PA measurements (P < .0001). Conclusion: PAN are potentially as reliable and reproducible as PA for the assessment of proximal bone height around dental implants.
机译:目的:本研究的目的是比较根尖片(PA)和全景片(PAN)在种植体周围的近端骨高测量中的作用。方法和材料:本研究选择了包含数字PAN和PA以及植入物长度和直径信息的患者文件。对于每张射线照相,植入物的尺寸用作校准的参考。一名检查员两次测量了近端放射照相的骨水平和骨顶与植入物肩之间的线性距离。配对t检验用于评估检查者内部变异性和两种射线照相方法之间的差异。然后使用Pearson相关系数检验评估相关性。显着性水平确定为5%。结果:对于PAN测量,从骨rest到种植体肩部的中位骨间距离为0.53和0.56 mm(第一组和第二组,P = 0.53)。同样,对于远端测量,这些读数分别为0.92和0.86 mm(P = 0.66)。对于PA测量,相应的测量分别为0.33和0.44 mm(P = 0.48)和0.99和0.99 mm(P = 0.42)。当比较PAN和PA测量值时,两种射线照相模式之间未检测到统计学上的显着差异。对于PAN-PA测量,获得了非常高的正相关(r> 0.91)(P <.0001)。结论:PAN在评估牙种植体周围的近端骨高方面,可能与PA一样可靠和可重复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号