首页> 外文期刊>Transactions of the ASABE >FINITE ELEMENT MODELING AND EXPERIMENTAL VALIDATION OF COOLING RATES OF LARGE READY-TO-EAT MEAT PRODUCTS IN SMALL MEAT-PROCESSING FACILITIES
【24h】

FINITE ELEMENT MODELING AND EXPERIMENTAL VALIDATION OF COOLING RATES OF LARGE READY-TO-EAT MEAT PRODUCTS IN SMALL MEAT-PROCESSING FACILITIES

机译:小肉加工设施中大型即食肉制品冷却速率的有限元建模和实验验证

获取原文
获取原文并翻译 | 示例
           

摘要

A two-dimensional axisymmetric transient heat conduction model was developed to simulate air chilling of large ready-to-eat meat products of ellipsoidal shape. A finite element scheme, using 1,600 linear triangular elements with 861 nodes, was implemented in Matlab 6.5 to solve the model. The model considered a variable initial temperature distribution and combined convective, radiative, and evaporative boundary conditions. Predicted values agreed well with experimental data collected in actual processing conditions. Validation of model performance resulted in maximum deviations of 2.54°C and 0.29% for temperature and weight loss histories, respectively. The maximum temperature deviation (2.54°C) occurred at the surface; however, for center temperature, the maximum deviation was lower (1.59°C). The validated model was used to assess the extent of deviations from stabilization performance standards established by the Food Safety and Inspection Service (FSIS) caused by unexpected equipment failure or electrical power outage. A total of 48 simulations were also carried out to establish critical product sizes and operating conditions for compliance with FSIS performance standards. It was concluded that, for cured meat products, small processors should be able to meet the stabilization requirements for any typical commercially available product size, under all simulated chilling conditions. Conversely, for non-cured meats, products should have a maximum weight of 2.25 kg (with typical dimensions of: major axis = 21.2 cm, minor axis = 13.9 cm) in order to comply with FSIS standards, particularly to meet the criteria of cooling between 54.4°C to 26.6°C. The validated model provides a useful quantitative tool for various food safety applications
机译:建立了二维轴对称瞬态热传导模型来模拟大型椭圆形即食肉制品的空气冷却。在Matlab 6.5中实现了使用1600个带有861个节点的线性三角形元素的有限元方案来求解模型。该模型考虑了可变的初始温度分布,并结合了对流,辐射和蒸发边界条件。预测值与在实际加工条件下收集的实验数据非常吻合。验证模型性能后,温度和失重历史的最大偏差分别为2.54°C和0.29%。表面出现最大温度偏差(2.54°C)。但是,对于中心温度,最大偏差较低(1.59°C)。经过验证的模型用于评估由于意外设备故障或电力中断而导致的与食品安全和检验服务(FSIS)建立的稳定性能标准之间的差异程度。还进行了总共48次仿真,以建立符合FSIS性能标准的关键产品尺寸和操作条件。得出的结论是,对于腌制肉制品,小型加工者应能够在所有模拟的冷藏条件下满足任何典型市售产品尺寸的稳定要求。相反,对于非腌制肉类,产品最大重量应为2.25千克(典型尺寸为:长轴= 21.2厘米,短轴= 13.9厘米),以便符合FSIS标准,尤其是要满足冷却标准54.4°C至26.6°C之间。经过验证的模型为各种食品安全应用提供了有用的定量工具

著录项

  • 来源
    《Transactions of the ASABE》 |2005年第1期|p.287-303|共17页
  • 作者单位

    Alejandro Amézquita, ASAE Member Engineer, Former Graduate Research Assistant, Department of Biological Systems Engineering, University of Nebraska, Lincoln, Nebraska, currently Project Leader, Safety and Environmental Assurance Centre, Unilever R&

    D Colworth, Sharnbrook, Bedfordshire, United Kingdom;

    Lijun Wang, ASAE Member Engineer, Research Assistant Professor, and Curtis L. Weller, ASAE Member Engineer, Professor, Department of Biological Systems Engineering, University of Nebraska, Lincoln, Nebraska. Corresponding author: Curtis L. Weller, Department of Biological Systems Engineering, University of Nebraska, 210 L.W. Chase Hall, Lincoln, Nebraska 68583-0726;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air chilling; Finite element analysis; Food safety; Heat transfer; Meat cooling;