首页> 外文期刊>Thin-Walled Structures >Capacity of steel CHS T-Joints strengthened with external stiffeners under axial compression
【24h】

Capacity of steel CHS T-Joints strengthened with external stiffeners under axial compression

机译:在轴向压力下用外部加强筋加强的CHS T型钢的连接能力

获取原文
获取原文并翻译 | 示例

摘要

The capacity of steel circular hollow section (CHS) T-joints reinforced with external stiffeners under axial compression is studied by finite element (FE) modeling and theoretical analysis in this paper. The FE modeling approach is first validated by results from axial compressive experiments on nine T-joints with and without stiffeners. Then 256 T-joint FE models are established and analyzed to investigate the influence of the size of external stiffeners and joint geometry on the improvement of ultimate capacity of the joints under axial compression. The results from parametric analysis show that the increment in ultimate capacity decreased when the diameter ratio between the brace and the chord beta increased, whereas it remained altnost proportional to the factor of stiffener length to the brace diameter eta. In addition, for such T-joints, when the thickness of external stiffener was no less than that of the chord wall, the effect of the factor of stiffen&thickness to the chord thickness lambda. and the diameter to thickness ratio of the chord 2 gamma on the improvement of ultimate capacity was not obvious. On the basil of the yield line model, a theoretical formula is further derived to predict the ultimate strength enhancement of reinforced T-joints with external stiffeners.
机译:通过有限元建模和理论分析,研究了外部加劲肋加固的圆形中空截面钢制T型节点的承载力。有限元建模方法首先通过对带有和不带有加劲肋的9个T型接头的轴向压缩实验的结果进行验证。然后建立并分析了256个T型接头有限元模型,以研究外部加强筋的尺寸和接头几何形状对轴向压缩下接头极限承载力提高的影响。参数分析的结果表明,当撑杆和弦β的直径比增加时,极限承载力的增加会减小,而与撑杆长度与撑杆直径eta的系数成正比的高度保持不变。另外,对于这种T形接头,当外部加劲肋的厚度不小于弦壁的厚度时,劲度和厚度对弦厚λ的影响。弦2γ的直径与厚度之比对极限承载力的改善不明显。在屈服线模型的罗勒上,进一步推导了理论公式,以预测使用外部加劲肋的增强T型接头的极限强度提高。

著录项

  • 来源
    《Thin-Walled Structures》 |2017年第4期|39-46|共8页
  • 作者单位

    Beijing Univ Civil Engn & Architecture, Beijing Higher Inst Engn Res Ctr Struct Engn & Ne, Sch Civil & Transportat Engn, Beijing, Peoples R China;

    Beijing Univ Civil Engn & Architecture, Beijing Higher Inst Engn Res Ctr Struct Engn & Ne, Sch Civil & Transportat Engn, Beijing, Peoples R China;

    Monash Univ, Dept Civil Engn, Clayton, Vic 3800, Australia;

    Beijing Univ Civil Engn & Architecture, Beijing Higher Inst Engn Res Ctr Struct Engn & Ne, Sch Civil & Transportat Engn, Beijing, Peoples R China;

    Beijing Univ Civil Engn & Architecture, Beijing Higher Inst Engn Res Ctr Struct Engn & Ne, Sch Civil & Transportat Engn, Beijing, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    CHS T-joint; Axial compression; External stiffener; Finite element method; Parametric analysis; Yield line model;