摘要

An optical biosensing system based on a standard CMOS technology and absorption photometry is proposed. Within the compact prototype, a CMOS sensor consisting a $hbox{P}^{+}/hbox{N}_{ {rm well}}$ finger photodiode and a transimpedance amplifier was implemented in a standard 0.35-$mu$ m CMOS technology. The $hbox{ABTS/H}_{2}hbox{O}_{2}/hbox{HRP}$ method was adopted to be coupled with various analytes of interest, such as glucose and histamine, which can serve as the basis for medical diagnosis. The experimental results demonstrate that the minimum concentrations successfully detected for $hbox{H}_{2}hbox{O}_{2}$ , glucose, and histamine are 1 $mu hbox{M}$, 1 $mu hbox{M}$, and 10 $mu hbox{M}$, respectively. The detection limits are at least one order of magnitude better than those of reported CMOS biosensors, and are even comparable to those of a commercial spectrophotometer.
机译:提出了一种基于标准CMOS技术和吸收光度法的光学生物传感系统。在紧凑型原型中,在标准的0.35-μmm CMOS中实现了由$ hbox {P} ^ {+} / hbox {N} _ {{rm well}} $手指光电二极管和跨阻放大器组成的CMOS传感器。技术。采用$ hbox {ABTS / H} _ {2} hbox {O} _ {2} / hbox {HRP} $方法与各种感兴趣的分析物(例如葡萄糖和组胺)结合,可以作为基础用于医学诊断。实验结果表明,成功检测到的$ hbox {H} _ {2} hbox {O} _ {2} $,葡萄糖和组胺的最低浓度分别为1 $ mu hbox {M} $,1 $ mu hbox {M } $和10 $ mu hbox {M} $。检测限比报道的CMOS生物传感器的检测限至少高一个数量级,甚至可以与商用分光光度计相媲美。