The degradation of insulation would be accelerated by the partial discharge (PD) incurred by an internal air-gap defect in oil-pressboard insulation. At different bridge rectifier locations in the converter transformer, the oil-pressboard insulation typically endures various ratios of combined ac and positive dc voltages. Therefore, the dielectric status of the converter transformer is closely correlated to the ratios of ac to dc voltages. It is practically significant to conduct the study of the correlation between discharge characteristics and ac-dc ratios. At the same time, it enhances the diagnosis of faults in converter transformers. According to the actual internal operation conditions of converter transformers, the study established a test platform. Furthermore, the conventional pulse current method was adopted to compare the discharge characteristics at the initiation and close-to-breakdown stages. Under these ratios, test results display distinctive PD dynamics. The PD of the air gap generates surface charges. These charges, in turn, establish an inverse electric field. As a result, the proportion of dc in the ac-dc combined voltage increases, and total initial voltage and total breakdown voltage increase continuously, but the recurrence rate of discharge pulse and discharge magnitude decrease at the initiation and close-to-breakdown stages. As the positive dc proportion increases, the discharge recurrence rate in the negative half cycle gradually exceeds that in the positive one. These research findings provide useful criteria for the fault diagnosis of converter transformers.
机译:压油板绝缘中的内部气隙缺陷引起的局部放电(PD)会加速绝缘的劣化。在换流变压器中不同的桥式整流器位置,油压板绝缘层通常可以承受各种组合的交流电压和直流正电压的比率。因此,转换器变压器的介电状态与交流电压与直流电压之比密切相关。进行放电特性与交流-直流比之间的相关性研究具有实际意义。同时,它增强了换流变压器故障的诊断能力。根据换流变压器的实际内部运行条件,研究建立了测试平台。此外,采用传统的脉冲电流法比较了初始和击穿阶段的放电特性。在这些比率下,测试结果显示出独特的PD动态。气隙的局部放电会产生表面电荷。这些电荷反过来建立了反向电场。结果,在交流-直流组合电压中直流的比例增加,总初始电压和总击穿电压连续增加,但是在启动和接近击穿阶段,放电脉冲的重复率和放电幅度降低。随着直流正比例的增加,负半周的放电重复率逐渐超过正半周。这些研究结果为换流变压器的故障诊断提供了有用的标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号