首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Application of very low energy neutron radiography with energy selection system using 4Qc(4m) supermirror
【24h】

Application of very low energy neutron radiography with energy selection system using 4Qc(4m) supermirror

机译:具有4Qc(4m)超镜的能量选择系统在超低能中子射线照相中的应用

获取原文
获取原文并翻译 | 示例

摘要

A high contrast neutron CT system is installed in the VCN/PF2 port of Institut Laue-Langevin and VCN port of Kyoto University Reactor (KUR). A converter + C-CCD system is used for the image detection. This system has an option of the energy selection system by neutron reflection on a 4Qc (4m) supermirror. The critical angle of the neutron reflection on this mirror is four times larger than that of natural nickel and the diameter is 20 cm. As the neutron reflection on a mirror removes faster neutrons, it can be used as a low pass filter of the neutron energy. The upper limit of the reflected neutron energy can be easily changed by the rotation of the mirror. As the application of this high contrast imaging system, the density nonuniformity of an aluminum welding sample can be shown by the refraction effect of very cold neutrons in VCN/PF2/ILL.
机译:高对比度中子CT系统安装在Laue-Langevin研究所的VCN / PF2端口和京都大学反应堆(KUR)的VCN端口中。转换器+ C-CCD系统用于图像检测。该系统可以通过在4Qc(4m)超级镜上进行中子反射来选择能量选择系统。该反射镜上的中子反射的临界角是天然镍的临界角的四倍,直径为20 cm。由于反射镜上的中子反射会去除较快的中子,因此可以用作中子能量的低通滤波器。反射镜的旋转可以很容易地改变反射中子能量的上限。作为这种高对比度成像系统的应用,铝焊接样品的密度不均匀性可以通过非常冷的中子在VCN / PF2 / ILL中的折射效应来显示。