首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Implementation of a parallel-beam optical-CT apparatus for three-dimensional radiation dosimetry using a high-resolution CCD camera
【24h】

Implementation of a parallel-beam optical-CT apparatus for three-dimensional radiation dosimetry using a high-resolution CCD camera

机译:使用高分辨率CCD相机实现用于三维辐射剂量学的平行光束光学CT设备

获取原文
获取原文并翻译 | 示例

摘要

In this study, a charge-coupled device (CCD) camera with 2-megapixel (1920 × 1080-pixel) and 12-bit resolution was developed for optical computed tomography(optical CT). The signal-to-noise ratio (SNR) of our system was 30.12 dB, better than that of commercially available CCD cameras (25.31 dB). The 50% modulation transfer function (MTF50) of our 1920 × 1080-pixel camera gave a line width per picture height (LW/PH) of 745, which is 73% of the diffraction-limited resolution. Compared with a commercially available 1-megapixel CCD camera (1296 × 966-pixel) with a LW/PH=358 and 46.6% of the diffraction-limited resolution, our camera system provided higher spatial resolution and better image quality. The NIPAM gel dosimeter was used to evaluate the optical CT with a 2-megapixel CCD. A clinical five-field irradiation treatment plan was generated using the Eclipse planning system (Varian Corp., Palo Alto, CA, USA). The gel phantom was irradiated using a 6-MV Varian Clinac Ⅸ linear accelerator (Varian). The measured NIPAM gel dose distributions and the calculated dose distributions, generated by the treatment planning software (TPS), were compared using the 3% dose-difference and 3 mm distance-to-agreement criteria. The gamma pass rate was as high as 98.2% when 2-megapixel CCD camera was used in optical CT. However, the gamma pass rate was only 96.0% when a commercially available 1-megapixel CCD camera was used.
机译:在这项研究中,开发了一种具有2兆像素(1920×1080像素)和12位分辨率的电荷耦合器件(CCD)相机,用于光学计算机断层摄影(optical CT)。我们系统的信噪比(SNR)为30.12 dB,优于市售CCD摄像机的信噪比(25.31 dB)。我们的1920×1080像素相机的50%调制传递函数(MTF50)给出的每图片高度线宽(LW / PH)为745,这是衍射极限分辨率的73%。与市售的LW / PH = 358且衍射极限分辨率为46.6%的1百万像素CCD相机(1296×966像素)相比,我们的相机系统提供了更高的空间分辨率和更好的图像质量。 NIPAM凝胶剂量计用于评估2百万像素CCD的光学CT。使用Eclipse计划系统(美国加利福尼亚州帕洛阿尔托的瓦里安公司)生成了临床五场辐射治疗计划。用6-MV Varian ClinacⅨ线性加速器(Varian)照射凝胶体模。使用3%剂量差异和3毫米协议距离标准比较由治疗计划软件(TPS)生成的NIPAM凝胶剂量分布和计算的剂量分布。当将2百万像素CCD相机用于光学CT时,伽玛通过率高达98.2%。但是,当使用市售的1兆像素CCD相机时,伽玛通过率仅为96.0%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号