Augmenting or interchanging current international safeguards shift register−based data acquisition systems with list mode data acquisition systems gives nondestructive assay (NDA) systems greater versatility. Neutron list mode data analysis offers comparable analytical results to the more widely used shift register analysis in nuclear material quantification applications and offers several diagnostic tools that are specifically beneficial to in-laboratory characterization and calibration measurements. These benefits include identification of non-ideal behavior, optimization of operational parameters from a single measurement, and an improved understanding of the physics-based behavior of NDA systems for a more precise system representation and more confident assay results. In this work the advantages of using list mode data acquisition for detector characterization are demonstrated experimentally. Two commercial-off-the-shelf International Atomic Energy Agency-supported technologies are used for a typical detector characterization procedure and their performance is compared. Specifically, a3He-based Canberra Industries JCC-71 Neutron Coincidence Collar is characterized using the Hungarian Institute of Isotopes’ Pulse Train Recorder-32 (PTR-32) list mode data acquisition system, and the results are compared to those obtained using the standard Canberra Industries JSR-15 model shift register. The quantitative results from the two systems are in agreement, which demonstrates that the PTR-32 is a technically viable alternative to conventional shift register electronics for this task. A suitable procedure for full instrument characterization is described, and the added benefits of list mode for characterization and data collection are discussed. This is an important step toward establishing a procedure for the routine use of list mode data acquisition and analysis for neutron NDA system characterization in safeguards field applications.
机译:通过列表模式数据采集系统增强或互换当前基于国际保障措施移位寄存器的数据采集系统,可以使无损检测(NDA)系统具有更大的通用性。中子列表模式数据分析可提供与核材料定量应用中更广泛使用的移位寄存器分析相当的分析结果,并提供几种特别有助于实验室表征和校准测量的诊断工具。这些好处包括识别非理想行为,通过单次测量优化操作参数以及对NDA系统基于物理行为的更好理解,从而获得更精确的系统表示和更自信的测定结果。在这项工作中,实验证明了使用列表模式数据采集进行检测器表征的优势。典型的检测器表征过程使用了两种国际现货供应的国际原子能机构支持的技术,并对它们的性能进行了比较。具体而言,基于3He的Canberra Industries JCC-71中子重合项圈的特征是使用匈牙利同位素研究所的Pulse Train Recorder-32(PTR-32)列表模式数据采集系统,并将结果与​​使用标准Canberra获得的结果进行比较行业JSR-15模型移位寄存器。两个系统的定量结果是一致的,这表明PTR-32在技术上是传统移位寄存器电子设备在该任务上的技术可行替代方案。描述了一种适用于全仪器表征的程序,并讨论了列表模式用于表征和数据收集的附加好处。这是建立保障程序现场应用中中子NDA系统表征常规使用列表模式数据采集和分析程序的重要一步。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号