首页> 外文期刊>Journal of Environmental Science and Health >Digital analysis technique for uncertainty reduction in colorimetric arsenic detection method
【24h】

Digital analysis technique for uncertainty reduction in colorimetric arsenic detection method

机译:比色砷检测方法中降低不确定度的数字分析技术

获取原文
获取原文并翻译 | 示例
           

摘要

This article proposes an alternative to increase the reliability and reproducibility of a colorimetric method to measure arsenic (As) concentrations. The method of analysis developed incorporates a digital analysis technique to eliminate the operator dependence of results, and As concentrations are quantitatively determined from digital levels computed from photographs of the colorimetric reaction that emerges during the test. This technique allows the sensitivity of the detection to be increased at low concentration ranges, which is of fundamental importance for the detection of As given the current acceptable limit for drinking water. The results obtained show a very good correlation between As concentrations determined by means of analytical laboratory techniques and the method proposed in this research.
机译:本文提出了一种替代方法,可以提高比色法测量砷(As)浓度的可靠性和可重复性。所开发的分析方法结合了数字分析技术,以消除操作员对结果的依赖性,并且从测试过程中出现的比色反应照片计算出的数字水平来定量确定As浓度。该技术允许在低浓度范围内提高检测灵敏度,这对于检测砷至关重要,因为当前饮用水的可接受极限。所得结果表明,通过分析实验室技术确定的砷浓度与本研究中提出的方法之间具有很好的相关性。