首页> 美国卫生研究院文献>other >Analysis of computer-aided detection techniques and signal characteristics for clustered microcalcifications on digital mammography and digital breast tomosynthesis
【2h】

Analysis of computer-aided detection techniques and signal characteristics for clustered microcalcifications on digital mammography and digital breast tomosynthesis

机译:数字化乳腺X线摄影和数字化乳房断层合成术中簇状微钙化的计算机辅助检测技术和信号特征分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

With IRB approval, digital breast tomosynthesis (DBT) images of human subjects were collected using a GE GEN2 DBT prototype system. Corresponding digital mammograms (DMs) of the same subjects were collected retrospectively from patient files. The data set contained a total of 237 views of DBT and equal number of DM views from 120 human subjects, each included 163 views with microcalcification clusters (MCs) and 74 views without MCs. The data set was separated into training and independent test sets. The preprocessing, object prescreening and segmentation, false positive reduction and clustering strategies for MC detection by three computer-aided detection (CADe) systems designed for DM, DBT, and a planar projection image generated from DBT were analyzed. Receiver operating characteristic (ROC) curves based on features extracted from microcalcifications and free-response ROC (FROC) curves based on scores from MCs were used to quantify the performance of the systems. Jackknife FROC (JAFROC) and non-parametric analysis methods were used to determine the statistical difference between the FROC curves. The difference between the CADDM and CADDBT systems when the false positive rate was estimated from cases without MCs did not reach statistical significance. The study indicates that the large search space in DBT may not be a limiting factor for CADe to achieve similar performance as that observed in DM.
机译:经过IRB的批准,使用GE GEN2 DBT原型系统收集了人类受试者的数字乳房断层合成(DBT)图像。回顾性地从患者档案中收集了相同受试者的相应数字乳房X线照片(DM)。数据集总共包含237个DBT视图和相等数量的120个人类受试者的DM视图,每个视图包括163个带有微钙化簇(MC)的视图和74个不带有MC的视图。数据集分为训练集和独立测试集。通过为DM,DBT设计的三个计算机辅助检测(CADe)系统以及从DBT生成的平面投影图像,分析了MC检测的预处理,对象预筛选和分割,假阳性减少和聚类策略。基于从微钙化中提取的特征的接收器工作特性(ROC)曲线和基于来自MC得分的自由响应ROC(FROC)曲线用于量化系统的性能。使用折刀FROC(JAFROC)和非参数分析方法来确定FROC曲线之间的统计差异。从没有MC的病例中估计假阳性率时,CADDM和CADDBT系统之间的差异没有统计学意义。研究表明,DBT中较大的搜索空间可能不是CADe获得与DM中观察到的类似性能的限制因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号