首页> 外文期刊>Japanese journal of applied physics >Experimental assessment of on-chip liquid cooling through microchannels with de-ionized water and diluted ethylene glycol
【24h】

Experimental assessment of on-chip liquid cooling through microchannels with de-ionized water and diluted ethylene glycol

机译:用去离子水和稀释的乙二醇通过微通道进行片上液体冷却的实验评估

获取原文
获取原文并翻译 | 示例

摘要

Recent progress in Si IC devices, which results in an increase in power density and decrease in device size, poses various thermal challenges owing to high heat dissipation. Therefore, conventional cooling techniques become ineffective and produce a thermal bottleneck. In this study, an on-chip liquid cooling module with microchannels and through Si via (TSV) was fabricated, and cooling characteristics were evaluated by IR measurements. Both the microchannels and TSVs were fabricated in a Si wafer by deep reactive ion etching (DRIE) and the wafer was bonded with a glass wafer by a anodic bonding. The fabricated liquid cooling sample was evaluated using two different coolants (de-ionized water and 70 wt% diluted ethylene glycol), and the effect of coolants on cooling characteristics was investigated. (C) 2016 The Japan Society of Applied Physics
机译:Si IC器件的最新进展导致功率密度的增加和器件尺寸的减小,由于高散热而带来了各种热挑战。因此,常规的冷却技术变得无效并产生热瓶颈。在本研究中,制造了具有微通道和通过硅过孔(TSV)的芯片上液体冷却模块,并通过IR测量评估了冷却特性。通过深反应离子刻蚀(DRIE)在硅晶片中制造微通道和TSV,并通过阳极键合将晶片与玻璃晶片键合。使用两种不同的冷却剂(去离子水和70 wt%稀释的乙二醇)评估了制成的液体冷却样品,并研究了冷却剂对冷却特性的影响。 (C)2016年日本应用物理学会

著录项

  • 来源
    《Japanese journal of applied physics》 |2016年第6s3期|06JB02.1-06JB02.5|共5页
  • 作者单位

    Seoul Natl Univ Sci & Technol, Grad Sch NID Fus Technol, Seoul 139743, South Korea;

    Seoul Natl Univ Sci & Technol, Dept Mech Syst Design Engn, Seoul 139743, South Korea;

    Seoul Natl Univ Sci & Technol, Grad Sch NID Fus Technol, Seoul 139743, South Korea;