Precise Calibration Method for Triaxial Magnetometers Not Requiring Earth’s Field Compensation

机译:不需要地球场补偿的三轴磁力计的精确校准方法

获取原文
获取原文并翻译 | 示例

摘要

A calibration procedure for calibrations of triaxial magnetometers is presented. The procedure uses a triaxial Helmholtz coil system and an Overhauser scalar magnetometer and is performed in the Earth’s field range. The triaxial coils are first calibrated with the Overhauser magnetometer, and subsequently, a triaxial magnetometer calibration is performed. As opposed to other calibration approaches, neither Earth’s field nulling system nor movements of the magnetometer are needed. A real calibration test was carried out—the extended calibration uncertainty was better than 430 ppm in sensitivity and 0.06° in orthogonality.
机译:介绍了用于校准三轴磁力计的校准程序。该程序使用三轴亥姆霍兹线圈系统和Overhauser标量磁力计,并在地球磁场范围内执行。首先使用Overhauser磁力计校准三轴线圈,然后执行三轴磁力计校准。与其他校准方法相反,既不需要地球磁场清零系统,也不需要磁力计的移动。进行了真正的校准测试-扩展的校准不确定度在灵敏度上优于430 ppm,在正交性方面优于0.06°。