首页> 外文期刊>Insight >Influence of acoustic transparency of surface contact layer on flaw detectability in ultrasonic testing
【24h】

Influence of acoustic transparency of surface contact layer on flaw detectability in ultrasonic testing

机译:表面接触层的透声度对超声检测中探伤能力的影响

获取原文
获取原文并翻译 | 示例
           

摘要

On the basis of extensive experiments, conducted on a representative sample of specimens with different kinds of autocorrelated function of surface profile, the following dependencies were obtained: 1. correlative links between parameters of regular and stochastic unevenness and absorption coefficient in the coupling layer for several ultrasonic transducers produced by firms such as Krautkramer, Sonatest, Tokimek, Volna and others; 2. correlative links between height parameters of unevenness and the amplitude of an auxiliary signal from the SRC-probe; 3. correlative links between absorption coefficient in coupling layer for ultrasonic transducers (normal transducers and angle transducers) and the amplitude of an auxiliary signal from the SRC-probe.
机译:在广泛的实验的基础上,对具有不同类型的表面相关自相关函数的代表性样品进行了研究,得出以下依赖关系:1.规则和随机凹凸参数与耦合层中吸收系数之间的相关联系由Krautkramer,Sonatest,Tokimek,Volna等公司生产的超声换能器; 2.不均匀的高度参数与来自SRC探针的辅助信号的幅度之间的相关链接; 3.超声换能器(正常换能器和角度换能器)耦合层中的吸收系数与SRC探针的辅助信号幅度之间的相关联系。