摘要

This paper presents a new technique to improve the input power factor of a single-phase rectifier followed by an inductive filter. It consists in the employment of a two-quadrant active power filter, based on a conventional bidirectional dc–dc converter, connected to the output side of the diode bridge. This technique allows the extension of this rectifier range operation in the continuous conduction mode. Circuit description, operation principle, modeling, design, and simulation results are presented in this paper. A laboratory prototype was designed and built with the following specifications: input voltage: 220 V $_{rm rms}$; output voltage: 200 V $_{rm dc}$; rated power: 3 kW; and switching frequency: 100 kHz. By the experimental results obtained, the system presented a unity power factor and an efficiency of 95% at full load, while the maximum efficiency value was 98% at 2 kW.
机译:本文提出了一种新技术,可改善单相整流器后接电感滤波器的输入功率因数。它包括采用基于传统双向dc-dc转换器的两象限有源功率滤波器,该滤波器连接到二极管电桥的输出侧。该技术允许在连续导通模式下扩展该整流器范围的工作。本文介绍了电路描述,工作原理,建模,设计和仿真结果。设计并制造了具有以下规格的实验室原型:输入电压:220 V $ _ {rm rms} $;输出电压:200 V $ _ {rm dc} $;额定功率:3 kW;和开关频率:100 kHz。通过获得的实验结果,该系统呈现出统一的功率因数,满载时的效率为95%,而在2 kW时的最大效率值为98%。