首页> 外文期刊>IEEE Transactions on Nuclear Science >Comparison of 180/spl deg/ and 360/spl deg/ iterative reconstruction with non-uniform attenuation compensation for Tl-201 SPECT
【24h】

Comparison of 180/spl deg/ and 360/spl deg/ iterative reconstruction with non-uniform attenuation compensation for Tl-201 SPECT

机译:Tl-201 SPECT具有非均匀衰减补偿的180 / spl deg /和360 / spl deg /迭代重建的比较

获取原文
获取原文并翻译 | 示例
           

摘要

This study compares Tl-201 SPECT images reconstructed from 180/spl deg/ and 360/spl deg/ projection data, using iterative reconstruction with non-uniform attenuation compensation. Using a mathematical phantom of the human thorax, Monte Carlo simulation is used to produce both 180/spl deg/ (45/spl deg/ RAO to 45/spl deg/ LPO) and 360/spl deg/ Tl-201 SPECT projection data. Included in the simulation are the effects of non-uniform attenuation, detector response, scatter and statistical noise. The 180/spl deg/ and 360/spl deg/ data were taken over 64 and 128 angles, respectively, assuming the same total acquisition time for both. The simulated projection data were reconstructed with nonuniform attenuation compensation using the ML-EM algorithm for 50 iterations and, for comparison, were also reconstructed without attenuation compensation using the filtered backprojection method with a ramp filter. Transaxial slices of the reconstructed images, image profiles and Bull's-eye plots all show that images reconstructed with attenuation compensation, unlike those reconstructed without attenuation compensation, are essentially the same within the region of the myocardium for the 180/spl deg/ and 360/spl deg/ data, with few artifacts and similar image contrast. Furthermore, for the same total imaging time, the images reconstructed from the 180/spl deg/ data have slightly less noise in the myocardial region.
机译:这项研究比较了使用具有非均匀衰减补偿的迭代重建从180 / spl deg /和360 / spl deg /投影数据重建的Tl-201 SPECT图像。使用人类胸部的数学模型,使用蒙特卡洛模拟来产生180 / spl deg /(45 / spl deg / RAO至45 / spl deg / LPO)和360 / spl deg / Tl-201 SPECT投影数据。模拟中包括不均匀衰减,检测器响应,散射和统计噪声的影响。假设这两个数据的总采集时间相同,则分别在64和128个角度上采集180 / spl deg /和360 / spl deg /数据。使用ML-EM算法对模拟投影数据进行了非均匀衰减补偿,并进行了50次迭代,并且为了进行比较,还使用带斜波滤波器的滤波反投影方法对模拟投影数据进行了无衰减补偿的重构。重建图像的轴向切片,图像轮廓和牛眼图均显示,与不进行衰减补偿的图像不同,使用衰减补偿的图像在心肌区域内对于180 / spl deg /和360 / s基本上相同。 spl deg /数据,几乎没有伪像和类似的图像对比度。此外,对于相同的总成像时间,从180 / spl deg /数据重建的图像在心肌区域的噪声略少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号