Analysis of volatile nitrosamines from a model system using SPME-DED at different temperatures and times of extraction

机译:使用SPME-DED在不同温度和萃取时间下对模型系统中的挥发性亚硝胺进行分析

获取原文
获取原文并翻译 | 示例
       

摘要

Solid-phase microextraction (SPME) coupled to a direct extraction device (DED) was evaluated as a method for extracting nitrosa-mine (NA) standard mix containing nine volatile nitrosamines from a solid food model system using several temperatures and times of extraction. The efficacy of extraction, the linearity of response and the sensitivity of this method for analysis of NA were determined at refrigeration (4℃) and room (25℃) temperature. Several extraction times (15, 30, 60,120 and 180min) were also tested. Analysis was carried out with gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. At 4℃ all NA were detected at all concentrations studied (ranged from 1 to 50 ng ml~(-1)) except for N-nitrosopyrrolidine (NPYR), N-nitrosomorpholine (NMOR) and N-nitrosodiphenilamine (NDPheA). Better results were obtained at 25℃ in terms of efficacy of extraction, linearity values (regression coefficients, R~2) and sensitivity values (limit of detection, LOD). Only 15 min of extraction time were enough to extract all NA from gelatines (10 ng ml~(-1)) at 25℃. None of the NA reached the equilibrium, even when long times of extraction (20 and 24 h) were evaluated. SPME-DED appears to be a rapid and suitable technique for extracting NA from model food system at both refrigeration and room temperatures.
机译:评价了与直接萃取装置(DED)耦合的固相微萃取(SPME),作为使用多种温度和萃取时间从固体食品模型系统中萃取含9种挥发性亚硝胺的亚硝胺(NA)标准混合物的方法。在冷藏(4℃)和室温(25℃)下,测定了萃取效率,响应线性和该方法对NA的分析灵敏度。还测试了几次提取时间(15、30、60,120和180分钟)。用气相色谱-质谱法(GC-MS)在选定的离子监测(SIM)模式下进行分析。在4℃下,在所有研究浓度(1至50 ng ml〜(-1))下均检测到所有NA,除了N-亚硝基吡咯烷(NPYR),N-亚硝基吗啉(NMOR)和N-亚硝基二苯胺(NDPheA)。在25℃提取效率,线性度值(回归系数,R〜2)和灵敏度值(检出限,LOD)方面取得了较好的结果。在25℃下,仅15分钟的提取时间就足以从明胶(10 ng ml〜(-1))中提取所有NA。即使评估了长时间的提取(20和24小时),也没有NA达到平衡。 SPME-DED似乎是一种在冷藏和室温下从模型食物系统中提取NA的快速且合适的技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号