首页> 外文期刊>IEEE Transactions on Electron Devices >An integrated mass flow sensor with on-chip CMOS interface circuitry
【24h】

An integrated mass flow sensor with on-chip CMOS interface circuitry

机译:具有片上CMOS接口电路的集成质量流量传感器

获取原文
获取原文并翻译 | 示例

摘要

A multielement monolithic mass flow sensor which developed for possible use in automotive and industrial process control applications is reported. The chip illustrates the use of a common microstructure (a thin dielectric window/diaphragm) for the simultaneous measurement of flow velocity (rate), flow direction, gas type, and pressure. These transducers are merged with on-chip interface electronics to amplify and multiplex the transducer signals, control on-chip actuators, perform self-test, reduce the number of external leads required, and demonstrate process compatibility with a p-well CMOS process. The on-chip circuitry also implements a bandgap sensor for the measurement of ambient temperature. Thus, the chip simultaneously monitors all parameters needed for the computation of true mass flow, requires only ten external leads, and delivers high-level buffered output signals.
机译:据报道,开发了一种多元素整体式质量流量传感器,可以在汽车和工业过程控制应用中使用。该芯片说明了使用共同的微结构(薄的介电窗/膜片)来同时测量流速(速率),流向,气体类型和压力。这些换能器与片上接口电子设备合并在一起,以放大和复用换能器信号,控制片上执行器,执行自检,减少所需的外部引线数量,并证明其与p阱CMOS工艺的兼容性。片上电路还实现了一个带隙传感器,用于测量环境温度。因此,该芯片可同时监视计算真实质量流量所需的所有参数,仅需要十根外部引线,并提供高水平的缓冲输出信号。