High-Sensitivity Charge-Transfer-Type pH Sensor With Quasi-Signal Removal Structure

机译:具有准信号去除结构的高灵敏度电荷转移型pH传感器

获取原文
获取原文并翻译 | 示例

摘要

Charge-transfer-type pH sensors can be used to improve pH sensitivity with enhanced signal-to-noise ratio by applying the charge-accumulation technique. Theoretically, the pH sensitivity improves directly with the accumulated count. However, in a conventional sensor structure, a quasi-signal resulting from low charge transfer efficiency limits the accumulated count. In this paper, an effective solution to the problem of the quasi-signal and the novel sensor structure are investigated.
机译:通过应用电荷积累技术,电荷转移型pH传感器可用于提高pH灵敏度,并提高信噪比。从理论上讲,pH灵敏度随计数的增加而直接提高。但是,在传统的传感器结构中,由于电荷传输效率低而产生的准信号限制了累加计数。本文研究了一种解决准信号和新型传感器结构的有效方法。