首页> 外文期刊>Journal of Chromatography & Separation Techniques >Development of an Improved HPLC-PDA Method for the Determination of Tolfenamic Acid in Meat and Milk
【24h】

Development of an Improved HPLC-PDA Method for the Determination of Tolfenamic Acid in Meat and Milk

机译:改进的HPLC-PDA法测定肉类和牛奶中的甲苯甲酸

获取原文
           

摘要

Tolfenamic acid (TA) is one of the non-steroidal anti-inflammatory drugs (NSAIDs) which are widely used as analgesic, anti-inflammatory and antipyretic drugs. In this study, we developed an improved detection method focusing on the validation of the TA residue using high performance liquid chromatography (HPLC) and a photodiode array (PDA) detector. TA in bovine, swine muscles and milk were analyzed using a C18 column (5 μm, 250 mm × 4.6 mm i.d.) and the mobile phase consisted of water with 0.1% phosphoric acid (eluent A) and 0.1% phosphoric acid in acetonitrile (ACN) (eluent B). Additionally, to optimize TA detection, liquid-liquid extraction (LLE) and additional purification steps were established to minimize the endogenous peaks and interferences. The developed method was validated through the limit of detection (LOD), the limit of quantification (LOQ), linearity, accuracy, and precision testing. TA in food samples were successfully detected after 20 min in chromatography. The LOQ was evaluated at 0.01 mg/kg and coefficient of determination of the linear regression (r2) was well over 0.99. The recovery rates ranged from 81.9-90.8%, 74.2-92.8% and 74.5-80.7% with relative standard deviations lower than 20% for bovine, swine muscles and milk, respectively, which corresponds to the CODEX International Food Standards guideline. Finally, the developed method has been applied for monitoring samples collected from the markets in major cities and proven great potential to be used as the confirmatory method to analyze and monitor TA residue in animal-based food products.
机译:甲苯酚酸(TA)是一种非甾体类抗炎药(NSAIDs),被广泛用作止痛,抗炎和退热药。在这项研究中,我们开发了一种改进的检测方法,重点是使用高效液相色谱(HPLC)和光电二极管阵列(PDA)检测器验证TA残留物。使用C18色谱柱(5μm,250 mm×4.6 mm内径)分析牛,猪肌肉和牛奶中的TA,流动相由水和0.1%磷酸(洗脱液A)和0.1%乙腈中的磷酸(ACN)组成)(洗脱液B)。此外,为了优化TA检测,建立了液-液萃取(LLE)和其他纯化步骤,以最大程度地减少内源峰和干扰。通过检测限(LOD),定量限(LOQ),线性,准确性和精密度测试对开发的方法进行了验证。色谱分析20分钟后,成功检测到食品样品中的TA。 LOQ评估为0.01 mg / kg,线性回归的测定系数(r2)超过0.99。牛,猪肌肉和牛奶的回收率分别为81.9-90.8%,74.2-92.8%和74.5-80.7%,相对标准偏差低于20%,这与CODEX国际食品标准指南相对应。最后,已开发的方法已用于监测从主要城市市场收集的样品,并被证明具有很大的潜力,可作为分析和监测动物性食品中TA残留的确认方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号