...
首页> 外文期刊>International Journal of Food Studies >Reproducibility and correlation between meat shear force measurements by Warner-Bratzler machine and a texturometer
【24h】

Reproducibility and correlation between meat shear force measurements by Warner-Bratzler machine and a texturometer

机译:通过Warner-Bratzler机测量的肉切力与纹理仪之间的可重复性和相关性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Tenderness has a prominent position on meat quality and is considered to be the sensory characteristic that most influences meat acceptance. Therefore, the aim of this study was to evaluate the accuracy and determine correlations among three different meat shear force techniques. Commercial samples of bovine Longissimus thoracis et lumborum (BLTL), Tensor fasciae latae (BTFL), Semitendinosus (BST), Psoas major (BPM), Biceps femoris (BBF) and swine Longissimus thoracis et lumborum (PLTL) were analyzed for pH, proximate composition, cooking loss and shear force with a classical Warner-Bratzler device and a TA-XT2 Texturometer equipped with shear blades 1 and 3 mm thick. The effect of different techniques in each studied muscle was statistically analyzed and regression curves were built. Results from the 1 mm blade were quite similar to the ones obtained with the Warner-Bratzler, however the results from 3 mm blade were overestimated (p<0.05). Significant correlation (p<0.01) among shear force technique using Warner-Bratzler and the ones using the Texturometer was observed (0.47 for 1 mm blade and 0.57 for the 3 mm blade). In conclusion, we found that the 1 mm blade and the Warner-Bratzler machine are reproducible for all tested muscles, while the 3 mm blade is not reproducible for the BTFL, BST, BPM, BBF, PLTL. There is a significant correlation between the results obtained by the classical Warner-Bratzler and the TA-XT2 Texturometer equipped with both blades. Therefore, TA-XT2 Texturometer equipped with the 1mm blade can perfectly replace the traditional Warner-Bratzler device.
机译:嫩度在肉质上具有重要地位,被认为是最影响肉类接受的感官特征。因此,本研究的目的是评估准确性,并确定三种不同的肉类剪切力技术之间的相关性。分析了牛胸腰肉(BLTL),筋膜张肌(BTFL),半腱肌(BST),大腰大肌(BPM),股二头肌(BBF)和猪胸腹腰肉(PLTL)的商业样品的pH值使用经典的Warner-Bratzler设备和配有1和3毫米厚剪切刀片的TA-XT2质地计,可确定组成,烹饪损失和剪切力。对每种研究的肌肉中不同技术的效果进行统计分析,并建立回归曲线。 1毫米刀片的结果与Warner-Bratzler获得的结果非常相似,但是3毫米刀片的结果被高估了(p <0.05)。在使用Warner-Bratzler的剪切力技术与使用纹理硬度计的剪切力技术之间,存在显着相关性(p <0.01)(1 mm刀片为0.47,3 mm刀片为0.57)。总之,我们发现1 mm的刀片和Warner-Bratzler机器对于所有测试的肌肉均具有可复制性,而3 mm的刀片对于BTFL,BST,BPM,BBF,PLTL则无法复制。经典的Warner-Bratzler和装有两个刀片的TA-XT2纹理仪所获得的结果之间存在显着的相关性。因此,配备1mm刀片的TA-XT2纹理仪可以完美替代传统的Warner-Bratzler设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号