Background: In this study, we evaluated the analytical performance and clinical potential of a one-step multiplex real-time PCR assay for the simultaneous detection of 14 types of respiratory viruses using the AdvanSure RV real-time PCR Kit (LG Life Sciences, Korea). Methods: Three hundred and twenty clinical specimens were tested with the AdvanSure RV real-time PCR Kit and conventional multiplex reverse transcription (RT)-PCR assay. The assay results were analyzed and the one-step AdvanSure RV real-time PCR Kit was compared with the conventional multiplex RT-PCR assay with respect to the sensitivity and specificity of the detection of respiratory viruses. Results: The limit of detection (LOD) was 1.31 plaque-forming units (PFU)/mL for human rhinoviruses (hRVs), 4.93 PFU/mL for human coronavirus HCoV-229E/NL63, 2.67 PFU/mL for human coronavirus HCoV-OC43, 18.20 PFU/mL for parainfluenza virus 1 (PIV)-1, 24.57 PFU/mL for PIV-2, 1.73 PFU/mL for PIV-3, 1.79 PFU/mL for influenza virus group (Flu) A, 59.51 PFU/mL for FluB, 5.46 PFU/mL for human respiratory syncytial virus (hRSV)-A, 17.23 PFU/mL for hRSV-B, 9.99 PFU/mL for human adenovirus (ADVs). The cross-reactivity test for this assay against 23 types of non-respiratory viruses showed negative results for all viruses tested. The agreement between the one-step AdvanSure multiplex real-time PCR assay and the conventional multiplex RT-PCR assay was 98%. Conclusions: The one-step AdvanSure RV multiplex real-time PCR assay is a simple assay with high potential for specific, rapid and sensitive laboratory diagnosis of respiratory viruses compared to conventional multiplex RT-PCR.
机译:背景:在这项研究中,我们评估了使用AdvanSure RV实时PCR试剂盒(韩国LG Life Sciences)同时检测14种呼吸道病毒的一步多路实时PCR的分析性能和临床潜力)。方法:使用AdvanSure RV实时PCR试剂盒和常规的多重逆转录(RT)-PCR测定法检测了320个临床标本。分析了测定结果,并将一步法AdvanSure RV实时PCR试剂盒与常规多重RT-PCR测定法在检测呼吸道病毒的敏感性和特异性方面进行了比较。结果:人类鼻病毒(hRVs)的检出限(LOD)为1.31噬菌斑形成单位(PFU)/ mL,人类冠状病毒HCoV-229E / NL63为4.93 PFU / mL,人类冠状病毒HCoV-OC43为2.67 PFU / mL ,对于副流感病毒1(PIV)-1为18.20 PFU / mL,对于PIV-2为24.57 PFU / mL,对于PIV-3为1.73 PFU / mL,对于甲型流感病毒(Flu)A为1.79 PFU / mL,59.51 PFU / mL对于FluB,对于人类呼吸道合胞病毒(hRSV)-A为5.46 PFU / mL,对于hRSV-B为17.23 PFU / mL,对于人类腺病毒(ADV)为9.99 PFU / mL。此测定法对23种非呼吸道病毒的交叉反应性测试显示,所有测试病毒均显示阴性结果。一步式AdvanSure多重实时PCR分析与常规多重RT-PCR分析之间的一致性为98%。结论:与传统的多重RT-PCR相比,一步式AdvanSure RV多重实时PCR检测是一种简单的检测方法,具有特异性,快速和灵敏的实验室诊断呼吸道病毒的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号