Introduction: Central venous catheterization is one of the most common medical procedures and is associated with such complications as misplacement and pneumothorax. Chest X-ray is among good ways for evaluation of these complications. However, due to patient’s excessive exposure to radiation, time consumption and low diagnostic value in detecting pneumothorax in the supine patient, the present study intends to examine bedside ultrasound diagnostic value in locating tip of the catheter and pneumothorax. Materials and methods: In the present cross-sectional study, all referred patients requiring central venous catheterization were examined. Central venous catheterization was performed by a trained emergency medicine specialist, and the location of catheter and the presence of pneumothorax were examined and compared using two modalities of ultrasound and x-ray (as the reference standard). Sensitivity, specificity, and positive and negative predicting values were reported. Results: A total of 200 non-trauma patients were included in the study (58% men). Cohen’s Kappa consistency coefficients for catheterization and diagnosis of pneumothorax were found as 0.49 (95% CI: 0.43-0.55), 0.89 (P<0.001), (95% CI: 97.8-100), respectively. Also, ultrasound sensitivity and specificity in diagnosing pneumothorax were 75% (95% CI: 35.6-95.5), and 100% (95% CI: 97.6-100), respectively. Conclusion: The present study results showed low diagnostic value of ultrasound in determining catheter location and in detecting pneumothorax. With knowledge of previous studies, the search still on this field.
机译:简介:中心静脉导管插入术是最常见的医疗程序之一,并伴有错位和气胸等并发症。胸部X光检查是评估这些并发症的好方法之一。但是,由于患者过度暴露于放射线,耗时且在仰卧患者中检测气胸的诊断价值较低,因此本研究旨在检查床旁超声对定位导管尖端和气胸的诊断价值。材料和方法:在本横断面研究中,检查了所有需要中心静脉导管插入的转诊患者。由受过训练的急诊医学专家进行中心静脉导管插入术,并使用两种超声和X射线检查方法(作为参考标准)检查并比较导管的位置和气胸的存在。报告了敏感性,特异性以及阳性和阴性预测值。结果:总共200名非创伤患者被纳入研究(男性占58%)。发现用于导管插入和诊断气胸的Cohen Kappa一致性系数分别为0.49(95%CI:0.43-0.55),0.89(P <0.001)和(95%CI:97.8-100)。此外,超声诊断气胸的敏感性和特异性分别为75%(95%CI:35.6-95.5)和100%(95%CI:97.6-100)。结论:本研究结果表明超声对确定导管位置和检测气胸的诊断价值低。有了先前的研究知识,搜索仍在该领域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号