首页> 外文期刊>BMC Musculoskeletal Disorders >Total hip arthroplasty following failure of tantalum rod implantation for osteonecrosis of the femoral head with 5- to 10-year follow-up
【24h】

Total hip arthroplasty following failure of tantalum rod implantation for osteonecrosis of the femoral head with 5- to 10-year follow-up

机译:钽棒植入失败导致股骨头坏死后的全髋关节置换术,随访5至10年

获取原文
           

摘要

Total hip arthroplasty (THA) with failure of tantalum rod implant for osteonecrosis of the femoral head (ONFH) will be the only choice for patients. However,it remains unknown whether tantalum rod implantation has an adverse effect on the survival time of implants following conversion to THA. The aim of this study was to retrospectively evaluate the clinical and radiographic outcomes of conversion to THA in patients who were previously treated with implantation of a tantalum rod. This study included 31 patients (39 hips), who underwent conversion to THA due to failure of core decompression with an implanted tantalum rod. Among these 31 patients, 26 patients were male and five patients were female. The mean age of these patients was 49.3?years old (range: 36–64?years old). The control group included 33 patients (40 hips), who underwent total hip replacement without tantalum rod implantation. The hip Harris score, implant wear, osteolysis, radiolucencies and surgical complications were recorded during the follow-up. The distribution of tantalum debris in the proximal, middle and distal periprosthetic femoral regions, radiolucent lines and osteolysis were analyzed on post-operative radiographs. There were no significant differences in Harris score, liner wear and complications between the two groups (P?>?0.05). Osteolysis and radiolucent lines more likely occurred in patients with tantalum debris distributed in three regions than in one or two regions (P?
机译:钽棒植入物失败导致股骨头坏死(ONFH)的全髋关节置换术(THA)将是患者的唯一选择。然而,钽棒植入对转化为THA后的植入物存活时间是否有不利影响仍是未知的。这项研究的目的是回顾性评估先前接受钽棒植入治疗的患者转化为THA的临床和影像学结果。这项研究包括31例患者(39髋),他们由于植入钽棒导致核心减压失败而接受了THA转换。在这31例患者中,男性26例,女性5例。这些患者的平均年龄为49.3岁(范围:36–64岁)。对照组包括33例患者(40髋),他们接受了完全的髋关节置换术而未植入钽棒。在随访期间记录了髋关节哈里斯评分,植入物磨损,溶骨,放射线透明度和手术并发症。在术后X光片上分析钽碎片在假体周围,中部和远端的股骨区域,射线可透线和溶骨的分布。两组之间的Harris评分,衬板磨损和并发症之间无显着差异(P≥0.05)。钽碎屑分布在三个区域的患者比一两个区域更容易发生骨溶解和射线可透性(P <0.05)。植入钽棒的THA患者的中期临床预后与未使用钽棒的患者的中期临床预后无差异,这表明钽屑不会增加衬管的磨损率。但是,假体周围的钽碎片在股骨近端,中部和远端区域的分布可能会增加股骨溶骨和射线可透线的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号