首页> 外文期刊>Current Pharmaceutical Biotechnology >A UPLC-MS/MS Assay for Simultaneous Determination of Two Antipsy- chotics and Two Antidepressants in Human Plasma and its Application in Clinic
【24h】

A UPLC-MS/MS Assay for Simultaneous Determination of Two Antipsy- chotics and Two Antidepressants in Human Plasma and its Application in Clinic

机译:同时测定人血浆中两种抗真菌药和两种抗抑郁药的UPLC-MS / MS分析方法及其在临床中的应用

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Antidepressants and antipsychotics are widely prescribed drugs for the treatment of mental diseases. Therapeutic drug monitoring (TDM) is recommended for patients taking these drugs to ensure pharmaceutical efficacy, medication compliance and prevent toxicity.Objective: An ultra-high performance liquid chromatography/tandem-mass spectrometry (UPLC-MS/MS) method was developed for simultaneous determination of two Antidepressants-Fluoxetine (FLU) and Escitalopram (ESC), and two antipsychotics-risperidone (RIS) and aripiprazole (ARI), in human plasma.Methods: The sample was processed by simple protein precipitation and the targeted analytes were separated on a C-18 column by gradient elution with a mobile phase containing 0.1% formic acid (v/v) and acetonitrile. All the analytes were qualitative and quantitative measured by electrospray ionization source with Multiple Reaction Monitoring (MRM) in positive ion mode. A total of 56 plasma samples were obtained from out- or in-patients who were taking the cited four drugs for further analysis.Results: The calibration curves for FLU, ESC, RIS and ARI were linear in the range of 45-1800, 4-320, 2-200 and 50-1800 ng/mL, respectively. The entire analytical time for the analytes was 7.0 min for each run and the extraction efficiency was more than 90%. The sample was stable within various storage conditions. The trough concentrations in patients were measured with the validated method.Conclusion: The developed method was successfully used for simultaneous determination of FLU, ESC, RIS and ARI in the plasma of the patients, which provides effective technical support for routine TDM of these four drugs and is of great clinic value for individual therapy.
机译:背景:抗抑郁药和抗精神病药是广泛用于治疗精神疾病的药物。建议对服用这些药物的患者进行治疗药物监测(TDM),以确保药物效力,药物依从性并防止毒性。目的:开发了一种同时进行超高效液相色谱/串联质谱(UPLC-MS / MS)的方法测定人血浆中的两种抗抑郁药氟西汀(FLU)和依西酞普兰(ESC)以及两种抗精神病药利培酮(RIS)和阿立哌唑(ARI)通过使用含有0.1%甲酸(v / v)和乙腈的流动相进行梯度洗脱,获得C-18色谱柱。使用正离子模式的多反应监测(MRM),通过电喷雾电离源对所有分析物进行定性和定量测量。从门诊或住院患者中获取了56种血浆样品,他们正在服用上述4种药物进行进一步分析。结果:FLU,ESC,RIS和ARI的校准曲线在45-1800范围内呈线性,4 -320、2-200和50-1800 ng / mL。每次运行中分析物的整个分析时间为7.0分钟,萃取效率超过90%。样品在各种储存条件下均稳定。结论:所建立的方法成功地同时测定了患者血浆中的FLU,ESC,RIS和ARI,为这四种药物的常规TDM提供了有效的技术支持。对个体治疗具有重要的临床价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号