首页> 外文期刊>IEEE Transactions on Control Systems Technology >Optimized Thermal-Aware Job Scheduling and Control of Data Centers
【24h】

Optimized Thermal-Aware Job Scheduling and Control of Data Centers

机译:优化的热感知作业调度和数据中心控制

获取原文
获取原文并翻译 | 示例

摘要

Analyzing data centers with thermal-aware optimization techniques is a viable approach to reduce energy consumption of data centers. By taking into account thermal consequences of job placements among the servers of a data center, it is possible to reduce the amount of cooling necessary to keep the servers below a given safe temperature threshold. We set up an optimization problem to analyze and characterize the optimal set points for the workload distribution and the supply temperature of the cooling equipment. Furthermore, under mild assumptions, we design and analyze controllers that regulate the system to the optimal state without knowledge of the current total workload to be handled by the data center. The response of our controller is validated by simulations and convergence to the optimal set points is achieved under varying workload conditions.
机译:使用热感知优化技术分析数据中心是减少数据中心能耗的可行方法。通过考虑作业在数据中心服务器之间的放置所带来的热量影响,可以减少将服务器保持在给定安全温度阈值以下所需的冷却量。我们设置了一个优化问题,以分析和表征工作负荷分布和冷却设备的供应温度的最佳设定点。此外,在温和的假设下,我们设计并分析了将系统调节至最佳状态的控制器,而无需了解数据中心当前要处理的总工作量。我们的控制器的响应通过仿真得到验证,并且在变化的工作负载条件下可以收敛到最佳设定点。