Radiological dose analysis depending on the examination condition for computed tomography measurement of abdominal body fat

机译:根据检查条件进行放射线剂量分析,以进行腹部体脂肪计算机断层扫描测量

获取原文
获取原文并翻译 | 示例

摘要

This study used the manufactured human model fat phantom to measure the radiological dose and to propose proper examination conditions. Here, 64-multi-detector computed tomography was used and scanning was performed with various tube voltages of 80, 100 and 120kVp with the human body phantom. The dose-length product (DLP) value, computed tomography (CT) value and the body fat area value of the research phantom were measured after scanning. The DLP value for each examination condition by scanning with changes in the examination conditions was 120 kVp; the highest value was 182.8 mGy cm with 250 mA. The highest value was - 114.4 for 120 kVp and 250 mA. The body fat area value was measured for each examination condition by scanning with various examination conditions; the highest value was 179 cm~2 for 120 kVp and 250 mA. However, the body fat area values for 100 and 120 kVp did not show a large difference. The data may be valuable for the diagnosis without changing the abdominal body fat and decrease in the exposure dose during the abdominal body fat CT examination with the low tube voltage.
机译:这项研究使用制造的人体模型脂肪模型来测量放射线剂量并提出适当的检查条件。在这里,使用了64多探测器计算机断层扫描,并使用人体模型在80、100和120kVp的各种管电压下进行扫描。扫描后测量研究体模的剂量长度乘积(DLP)值,计算机断层扫描(CT)值和体脂面积值。通过随检查条件的变化进行扫描而得到的每个检查条件的DLP值为120kVp;最高值为250 mA时的182.8 mGy cm。对于120 kVp和250 mA,最高值为-114.4。通过用各种检查条件进行扫描来测量每种检查条件下的体脂面积值。 120 kVp和250 mA时的最大值为179 cm〜2。但是,100和120 kVp的体脂面积值没有显示出很大的差异。该数据对于在不改变腹部脂肪和在低管电压下进行腹部脂肪CT检查期间减少暴露剂量的情况下可能具有诊断价值。

著录项

  • 来源
    《Computer methods in biomechanics and bio》 |2016年第6期|368-373|共6页
  • 作者单位

    Department of International Radiological Science, Hallym University of Studies, Seoul, Republic of Korea;

    Department of Computer Science and Engineering, Soonchunhyang University, Asan, Republic of Korea;

    Department of Computer Science and Engineering, Soonchunhyang University, Asan, Republic of Korea,Department of Radiology, Soonchunhyang University Hospital, Bucheon, Gyeonggi-do 420-767, Republic of Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    body fat area value; dose-length product value; computed tomography value;

    机译:体脂面积值;剂量长度乘积值;计算机体层摄影术值;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号