In November 1999, bonded fiber-reinforced polymer (FRP) laminates were used to strengthen a single span, reinforced concrete T-beam bridge in New York State. The laminate system was installed to strengthen the structure in flexure and shear, and to contain observed freeze-thaw cracking. The bridge was then instrumented and load tested before and after installation of the laminates, to evaluate effectiveness of the strengthening FRP system. In November 2001, the load test was repeated to monitor in-service performance of the system. The test results indicated that the quality of bond between the laminates and concrete, and effectiveness of the system have not deteriorated after two years of service. Further inspection using an Infrared thermography camera did not show any significant delamination in the system, in agreement with the test results.
机译:1999年11月,粘合纤维增强聚合物(FRP)层压板用于加固纽约州的单跨钢筋混凝土T型梁桥。安装层压系统以增强结构的挠曲和剪切力,并包含观察到的冻融裂纹。然后,在安装层压板之前和之后,对桥梁进行检测并进行载荷测试,以评估强化FRP系统的有效性。在2001年11月,再次进行了负载测试以监视系统的运行性能。测试结果表明,在使用两年后,层压板与混凝土之间的粘结质量以及系统的有效性并未降低。与测试结果一致,使用红外热像仪进行的进一步检查未显示系统中有任何明显的分层。