首页> 外文期刊>IEEE Transactions on Biomedical Engineering >In-vivo measurement of swine myocardial resistivity
【24h】

In-vivo measurement of swine myocardial resistivity

机译:猪心肌电阻率的体内测量

获取原文
获取原文并翻译 | 示例

摘要

We used a four-terminal plunge probe to measure myocardial resistivity in two directions at three sites from the epicardial surface of eight open-chest pigs in-vivo at eight frequencies ranging from 1 Hz to 1 MHz. We calibrated the plunge probe to minimize the error due to stray capacitance between the measured subject and ground. We calibrated the probe in saline solutions contained in a metal cup situated near the heart that had an electrical connection to the pig's heart. The mean of the measured myocardial resistivity was 319 /spl Omega//spl middot/cm at 1 Hz down to 166 /spl Omega//spl middot/cm at 1 MHz. Statistical analysis showed the measured myocardial resistivity of two out of eight pigs was significantly different from that of other pigs. The myocardial resistivity measured with the resistivity probe oriented along and across the epicardial fiber direction was significantly different at only one out of the eight frequencies. There was no significant difference in the myocardial resistivity measured at different sites.
机译:我们使用了一个四端插入探针,以八个频率从1 Hz到1 MHz的频率从八只开胸的猪的心外膜表面的三个位置在两个方向上测量了心肌电阻率。我们对插入式探头进行了校准,以最大程度地减少由于被测对象与地面之间的杂散电容引起的误差。我们用位于靠近心脏的金属杯中的盐溶液校准了探头,该金属杯与猪的心脏有电连接。测得的心肌电阻率的平均值在1 Hz时为319 / splΩ// spl中点/ cm,在1 MHz时降至166 / splΩ// spl中点/ cm。统计分析表明,八头猪中有两只的测得的心肌电阻率与其他猪明显不同。沿着并沿心外膜纤维方向定向的电阻率探头测得的心肌电阻率在八种频率中只有一种显着不同。在不同部位测得的心肌电阻率无显着差异。